D40A/G9SX-NS
8
Characteristics
*1.
When two or more Units are connected
b
y logical AND, the operating time and response time are the sum total of the operating times and
response times, respectively, of all the Units connected
b
y logical AND.
*2.
Represents the operating time when the safety input turns ON with all other conditions set.
*3.
Represents the operating time when the logical AND input and the Non-contact Door Switch input turn ON with all other conditions set.
*4.
This does not include the operating time or response time of G9SX-NS
@
that are connected.
*5.
This does not include the operating time or response time of internal relays in the G9SX-EX-
@
.
*6.
The failure detection time for 24 V short-circuit failure on the input to Non-contact Door Switches is
3
5 ms max.
If using the Switch for an application other than as a Door Switch, calculate the safe distance using a failure detection time of
3
5 ms.
Item
Model
G9SX-NS202-
@
G9SX-NSA222-T0
3
-
@
G9SX-EX-
@
Over-volta
g
e cate
g
ory
(IEC/EN 60664-1)
II
II (Relay outputs 1
3
to 4
3
and 14
to 44: III)
Operatin
g
time (OFF to ON state)
*
1
100 ms max. (Logical AND
connection input ON and
Non-contact Door Switch input
ON)
50 ms max. (Safety input: ON)
*
2
100 ms max. (Logical AND
connection input ON and
Non-contact Door Switch input ON)
*
3
3
0 ms max.
*
4
Response time (ON to OFF state)
*
1
15 ms max. (Logical AND
connection input: OFF)
20 ms max. (Non-contact Door
Switch input OFF)
*
6
15 ms max. (Safety input OFF and
logical AND connection input OFF)
20 ms max. (Non-contact Door
Switch input: OFF)
*
6
10 ms max.
*
4
ON-state residual volta
g
e
3
.0 V max. (safety output, auxiliary output)
OFF-state leaka
g
e current
0.1 mA max. (safety output, auxiliary output)
Maximum wirin
g
len
g
th of safety
input, lo
g
ical AND connection
input, and Non-contact Door Switch
input
100 m max. (External connection impedance: 100
Ω
max. and 10 nF max.)
Reset input time
(Reset button pressin
g
time)
100 ms min.
Accuracy of OFF-delay time
*
5
---
Within
±
5% of the set value
Within
±
5% of the set value
Insulation
resistance
Between lo
g
ical AND
connection terminals,
and power supply input
terminals and other
input and output
terminals connected
to
g
ether
20 M
Ω
min. (at 100 VDC)
---
Between all terminals
connected to
g
ether and
DIN rail
100 M
Ω
min.
(at 500 VDC)
Dielectric
stren
g
th
Between lo
g
ical AND
connection terminals,
and power supply input
terminals and other
input and output
terminals connected
to
g
ether
500 VAC for 1 min.
---
Between all terminals
connected to
g
ether and
DIN rail
1,200 VAC for 1 min
Between different poles
of outputs
---
Between relay outputs
connected to
g
ether and
other terminals
connected to
g
ether
2,200 VAC for 1 min
Vibration resistance
10 to 55 to 10 Hz, 0.
3
75 mm single amplitude (0.75 mm dou
b
le amplitude)
Shock
resistance
Destruction
3
00 m/s
2
Malfunction
100 m/s
2
Durability
Electrical
---
100,000 cycles min. rated load,
switching frequency: 1,800
cycles/hour)
Mechanical
---
5,000,000 cycles min. (switching
frequency: 7,200 cycles/hour)
Ambient operatin
g
temperature
−
10 to 55
°
C (no icing or condensation)
Ambient operatin
g
humidity
25% to 85%
Terminal ti
g
htenin
g
torque
0.5 N·m (For the G9SX-NS
@
-RT (with screw terminals) only)
Wei
g
ht
Approx. 125 g
Approx. 200 g
Approx. 165 g