background image

RELAY TERMINAL

0631610-1 B

Thank you for purchasing an OMRON product.

Confirm product which must be required and read this manual

throughly for correct use before actually using it.

Keep this manual for reference.

This manual describes only the main precautions to be observed.

■ Accessories(Sold Separately)

●Do not submit the product to abnormal shock. Doing so might result in faulty operation.

●Use the Unit with the correct power supply voltage. An incorrect power supply may result in a problem.

●Double-check all the wiring before turning on the power supply. 

 Incorrect wiring may result in burning.

●Do not bend the cables beyond their natural limit. Doing so may break the cables. 

●Do not pull the cables by the power beyond 30N. Doing so may break the cables.

Be sure to turn off the power supply before wiring. Once the power is turned on, keep the cover 

 closed and do not touch the terminal block, otherwise an electrical shock accident may occur.

●Ensure DIN rail attachment or screw attachment.

●Never use the product under any load that exceeds the rated contact values including the switching 

 capacities, otherwise the product will not operate correctly and damage or burning may occur with

 the product itself.

●Take appropriate measures to ensure that the specified power with the rated voltage and frequency is 

 supplied. Be particularly careful in places where the power supply is unstable. An incorrect power 

 supply may result in malfunction.

●Do not attempt to disassemble, repair, or modify any Units. Any attempt to do so may result in 

 malfunction, fire, or electric shock.

●Apply specified voltage correctly to the input terminal. Application of wrong voltage will spoil the

 specified performance of this product and may break or burn the product itself.

●Do not install the Unit in any of the following locations. Installing the Unit in the following locations may

 result in malfunction, electric shock, or burning.

 ・Locations subject to condensation as the result of severe changes in temperature.

 ・Locations subject to corrosive or flammable gases.

 ・Locations subject to exposure to water, oil, or chemicals.

 ・Locations subject to direct sunlight.

 ・Locations subject to dust (especially iron dust) or salts.

 ・Locations subject to shock or vibration.

 ・Locations subject to temperatures or humidities outside the range specified in the specifications

●Take appropriate and sufficient countermeasures when installing systems in the following locations.

 Inappropriate and insufficient measures may result in malfunction.

 ・Locations close to power supplies.

 ・Locations subject to static electricity or other forms of noise.

 ・Locations subject to strong electromagnetic fields.

●When mounting a Relay, press the upper part of the Relay straight down until the Relay is locked with

 the hooks while making sure that none of the Relay terminals are bent.

 Not doing so may cause the I/O Terminal to malfunction or radiate heat.

Never use paint thinner or similar solvents, which can discolor or dissolve the sunface of the Unit.

●Avoid connecting and disconnecting connectors while the power is ON. Otherwise, misoperation may

 occur.

G70D(R)-SOC08

●G70R-SOC08

■ Terminal Arrangement / Connecting External

 

●G70D-SOC08

●G70R-SOC08

■ Dimensions  (Unit : mm)

●G70D-SOC08

●G70R-SOC08

・Be sure to mount using M4 screws or mount at a 35mm DIN rail using the DIN rail attachment hook.

  Do not install the product in places to be touched by accident toavoid malfunction caused by statick

  electricity.

・Since the voltage to be applied is specified, supply the power that meets the voltage specification to the

  terminals (24V, 0V) when using the relay terminal. The terminals (A0〜7, B0〜7) are contact outputs.

  Therefore supply the power that meets the load. Short-circuit boards are also available.

・The power take-in terminals serve to supply the relay drive power and the controller output transistor

  power. Match the controller voltage with the relay terminal voltage. Use the power supply having least 

  noise.

■ Internal Circuit

●G70D-SOC08

Connector is of 20-pin type and

11〜18 are open.

RY100…(1)20

RY101…(2)18

RY102…(3)16

RY104…(4)14

RY105…(5)12

RY106…(6)10

RY107…(7)  8

RY108…(8)  6

0V…(9)  4

24V…(10)2

19(11)

17(12)

15(13)

13(14)

11(15)

  9(16)

  7(17)

  5(18)

  3(19)…0V

  1(20)…24V

▲mark

Arrengement of Connector Pins

(TOP VIEW)

Connector is of 20-pin type and

11〜18 are open.

RY100…(1)20

RY101…(2)18

RY102…(3)16

RY103…(4)14

RY104…(5)12

RY105…(6)10

RY106…(7)  8

RY107…(8)  6

0V…(9)  4

24V…(10)2

19(11)

17(12)

15(13)

13(14)

11(15)

  9(16)

  7(17)

  5(18)

  3(19)…0V

  1(20)…24V

▲mark

Arrengement of Connector Pins

(TOP VIEW)

Applicable model
   G70D-SOC08
   G70R-SOC08

Coil rated voltage
        24VDC
        24VDC
        

    Model
G6D-1A-ASI
G2R-1-S(N)

      Applicable model
        G70D-SOC08
        G70R-SOC08

  model

    G6B-4-SB

●Replacement Relays

●Connector Cable

●Short Bar

24V   0V

B0

B1

B2

B3

A0

A1

A2

A3

24VDC

Load

Load

Load

Load

Load

Load

Load

Load

B4

B5

B6

B7

A4

A5

A6

A7

24V   0V

B0 B1 B2 B3 B4 B5 B6 B7
A0 A1 A2 A3 A4 A5 A6 A7

24VDC

Load

Load

Load

Load

Load

Load

Load

Load

LED101

LED102

LED103

LED104

LED105

LED106

LED107

LED100

RY100

20

18

16

14

12

10

8

6

RY101

RY102

RY103

RY104

RY105

RY106

RY107

1

2

3

4

C1

D1

24V

0V

B0

A0

B1

A1

B2

A2

B3

A3

B4

A4

B5

A5

B6

A6

B7

A7

RY100

20

18

16

14

12

10

8

6

1

2

3

4

C1

D1

24V

0V

B0

A0

B1

A1

B2

A2

B3

A3

B4

A4

B5

A5

B6

A6

B7

A7

RY101

RY102

RY103

RY104

RY105

RY106

RY107

136.2

68.2

54.6

92.8

43.5

92.8

7.1

7.1

When the product is used under the circumstances or environment below, ensure adherence
to limitations of the ratings and functions. Also, take countermeasures for safety precations 
such as fail-safe installations.
1.Use under circumstances or envrionment which are not described in described instruction manual.
2.Use for nuclear power control, railway, aircraft, vehicle, incinerator, medical 
   equipment, entertainment equipment, safety device etc.
3.Use for applications where death or serious property dameges is possible and
   extensive safety precautions are required.

        Error rate (level P, reference value)
               5VDC      1mA
               5VDC  100mA

Printed in Japan

・Cable with Loose Wire and Crimp Terminals : XW2Z-RY□C
・Cable with Loose Wires : XW2Z-RA□C
・Cable with connectors

 ‒ Fujitsu connectors(1:1) : XW2Z-R□C
  Fujitsu connectors(1:2) : XW2Z-RI□C-□ , XW2Z-RO□C-□

Fujitsu connectors(1:3) : XW2Z-R□C-□-□

 ‒ MIL connectors(1:1) : XW2Z-RI□C , XW2Z-RO□C
 ‒ MIL connectors(1:2) : XW2Z-RI□-□-D□ , XW2Z-RM□-□-D□ , XW2Z-RO□-□-D1

* Check the internal circuit before use and confirm the pins to be used.

  Refer to the XW2Z-R Datesheet(Cat. No. G126) for details.

Reviews: