Ratchet Relay

 G4Q

211

Operation

Note:

When a pulse for application to the coil is used, such a pulse
should have a width of 100 ms or more. If a pulse is applied with
a width less than the operate time, the cam may fail to rotate
fully.

Dimensions

Note:

All units are in millimeters unless otherwise indicated.

Ambient Temperature  vs. 
Coil Temperature  Rise

100 VAC 50 Hz

Coil temper

ature r

ise (  C)

°

Contact carry current: 5 A

Contact with no carry current

Ambient temperature (

°

C)

24 VDC

Coil temper

ature r

ise (  C)

Contact carry current: 5 A

Contact with no carry current

Ambient temperature (

°

C)

Malfunctioning Shock

Not 
energized

Energized

Unit: m/s

2

Number of samples: 5

Measurement conditions:  
Impose a shock of  
100 m/s

2

 in the 

±

X, 

±

Y, and 

±

Z directions three times  

each with the Relay  
energized and not  
energized to check the  
shock values that cause  
the Relay to malfunction.

Shock direction

°

100 ms min.

Contact terminal
(NO) (1

3, 8

6)

Contact terminal
(NC) (1

4, 8

5)

Coil terminal

Operation Timing  Chart

66.5 max. 58

Four, 3.5-dia. 
mounting holes

25

56 max.

65 max.

Four, M3 mounting 
screw holes or four 
3.5-dia. holes

Open Model

G4Q-211A

Terminal Arrangement/
Internal Connections

Mounting Holes

58

±

0.2

25

±

0.2

Summary of Contents for G4Q

Page 1: ... 6 4 VA DC approx 3 9 W Ordering Information Open Models Plug in Models Model Number Legend 1 Contact Form 2 DPDT 2 Contact Type 1 Single 3 Enclosure Construction 1 No casing 2 Casing 4 Terminal Shape A Solder S Plug in Item DPDT Rated voltage V Model Basic model 6 VAC G4Q 211A 12 VAC 24 VAC 50 VAC 100 110 VAC 200 220 VAC 6 VDC 12 VDC 24 VDC 48 VDC 100 VDC 200 VDC Item DPDT Rated voltage V Model B...

Page 2: ...erminal Solder terminal 8PFA1 PL08 Item Current mA Resistance Ω Must operate Must release Max voltage Power consumption Rated voltage V 50 Hz 60 Hz of rated voltage Initial Rated AC 6 1 233 1 067 0 54 80 max 10 min 110 max Approx 13 5 VA Approx 6 4 VA 12 614 531 2 24 24 307 266 8 7 50 148 128 42 7 100 110 74 64 73 5 160 200 220 37 32 36 8 671 Item Current mA Resistance Ω Must operate Must release ...

Page 3: ...ntact 1 000 VAC 50 60 Hz for 1 min between con tacts of same polarity 2 000 VAC between contacts of different polarities Vibration resistance Destruction 10 to 55 to 10 Hz 0 75 mm single amplitude 1 5 mm double amplitude Malfunction 10 to 55 to 10 Hz 0 5 mm single amplitude 1 0 mm double amplitude Shock resistance Destruction 500 m s2 Malfunction 100 m s2 Endurance Mechanical 5 000 000 operations ...

Page 4: ...ature rise C Contact carry current 5 A Contact with no carry current Ambient temperature C Malfunctioning Shock Not energized Energized Unit m s2 Number of samples 5 Measurement conditions Impose a shock of 100 m s2 in the X Y and Z directions three times each with the Relay energized and not energized to check the shock values that cause the Relay to malfunction Shock direction 100 ms min Contact...

Page 5: ... Relay The width of the Relay is 63 5 mm and the width of the Socket is 51 mm Mounting Mount the Relay so that the coil faces upward and the cam faces downwards with the mounting plate secured vertically Do not change the cam angle Make sure that Relay terminals are free of flux or any other foreign substance before soldering the Relay terminals 92 5 max 71 5 max 30 5 63 5 max 80 max Plug in Termi...

Reviews: