Ratchet Relay

 

G4Q

Characteristics

Note: 1.

The data shown above are initial values.

2.

The contact resistance was measured with 0.1 A at 5 VDC using the voltage drop method.

3.

The operate time was measured with the rated voltage imposed with any contact bounce ignored at an ambient temperature of 23

°

C.

4.

The insulation resistance was measured with a 500-VDC megger applied to the same places as those used for checking the dielectric
strength.

5.

The electrical endurance was measured at an ambient temperature of 23

°

C.

6.

This value was measured at a switching frequency of 60 operations per minute. The value in parentheses is for the cased model.

Engineering Data

Contact resistance (See note 2.)

50 m

 max.

Operate time (See note 3.)

60 ms max.

Max. operating frequency

Mechanical:

1,200 operations/hr

Electrical:

1,200 operations/hr (under rated load)

Insulation resistance (See note 4.)

100 M

 min. (at 500 VDC)

Dielectric strength

2,000 VAC, 50/60 Hz for 1 min between coil and contact (1,000 VAC, 50/60 Hz for 1 min between con-
tacts of same polarity) (2,000 VAC between contacts of different polarities)

Vibration resistance

Destruction: 

10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude)

Malfunction: 

10 to 55 to 10 Hz, 0.5 mm single amplitude (1.0 mm double amplitude)

Shock resistance

Destruction: 500 

m/s

2

Malfunction: 100 

m/s

2

Endurance

Mechanical:

 5,000,000 operations min. (at operating frequency of 1,200 operations/hr)

Electrical:

 500,000 operations min. (under rated load and at operating frequency of 
1,200 operations/hr) (See note 5.)

Error rate (See note 6.)

1 A at 5 VDC (0.1 A at 5 VDC)

Ambient temperature

Operating:

–10

°

C to 55

°

C (with no icing or no condensation)

Ambient humidity

Operating:

5% to 85%

Weight

Open model:  Approx. 240 g; cased model: Approx. 340 g

Maximum Switching Power

DC resistive load

AC resistive load

AC inductive load 
(cos

φ

 = 0.4)

DC inductive load
L/R = 7 ms

Switching current (A)

Switching voltage (V)

220 VAC resistive load

24 VDC resistive load

24VDC inductive load
L/R = 7 ms

220 VAC inductive load
(cos

φ

 = 0.4)

Electrical Endurance

Switching current (A)

Endur

ance (x10  oper

ations)

3

100

300

500

700

1,000

3,000

5,000

7,000

10,000

70
50

30

Summary of Contents for G4Q

Page 1: ... 6 4 VA DC approx 3 9 W Ordering Information Open Models Plug in Models Model Number Legend 1 Contact Form 2 DPDT 2 Contact Type 1 Single 3 Enclosure Construction 1 No casing 2 Casing 4 Terminal Shape A Solder S Plug in Item DPDT Rated voltage V Model Basic model 6 VAC G4Q 211A 12 VAC 24 VAC 50 VAC 100 110 VAC 200 220 VAC 6 VDC 12 VDC 24 VDC 48 VDC 100 VDC 200 VDC Item DPDT Rated voltage V Model B...

Page 2: ...erminal Solder terminal 8PFA1 PL08 Item Current mA Resistance Ω Must operate Must release Max voltage Power consumption Rated voltage V 50 Hz 60 Hz of rated voltage Initial Rated AC 6 1 233 1 067 0 54 80 max 10 min 110 max Approx 13 5 VA Approx 6 4 VA 12 614 531 2 24 24 307 266 8 7 50 148 128 42 7 100 110 74 64 73 5 160 200 220 37 32 36 8 671 Item Current mA Resistance Ω Must operate Must release ...

Page 3: ...ntact 1 000 VAC 50 60 Hz for 1 min between con tacts of same polarity 2 000 VAC between contacts of different polarities Vibration resistance Destruction 10 to 55 to 10 Hz 0 75 mm single amplitude 1 5 mm double amplitude Malfunction 10 to 55 to 10 Hz 0 5 mm single amplitude 1 0 mm double amplitude Shock resistance Destruction 500 m s2 Malfunction 100 m s2 Endurance Mechanical 5 000 000 operations ...

Page 4: ...ature rise C Contact carry current 5 A Contact with no carry current Ambient temperature C Malfunctioning Shock Not energized Energized Unit m s2 Number of samples 5 Measurement conditions Impose a shock of 100 m s2 in the X Y and Z directions three times each with the Relay energized and not energized to check the shock values that cause the Relay to malfunction Shock direction 100 ms min Contact...

Page 5: ... Relay The width of the Relay is 63 5 mm and the width of the Socket is 51 mm Mounting Mount the Relay so that the coil faces upward and the cam faces downwards with the mounting plate secured vertically Do not change the cam angle Make sure that Relay terminals are free of flux or any other foreign substance before soldering the Relay terminals 92 5 max 71 5 max 30 5 63 5 max 80 max Plug in Termi...

Reviews: