background image

G3PA-(VD)

G3PA-(VD)

142

G32A-A10/G32A-A20

Use the special tool (provided) to extract the cartridge for replace-
ment with a new one.

Extraction

Follow the procedures below to dismount the Power Device Car-
tridge from the G3PA.

1. Switch off the power.

2. Remove the terminal cover.

3. Hook the indented part of the cartridge with the tool and pull

up on the cartridge to remove it.

Remover

Hook here with
Remover.

Mounting

Follow the procedures below to mount the Power Device Cartridge
on the G3PA.

1. Apply silicone grease (provided with the G32A-A) to the entire

surface of the heat radiator.

Apply silicone grease here.

2. Make sure that there is no dust or pieces of wire on the heat

radiator of the G32A-A or the G3PA.

3. Insert the cartridge into the opening of the G3PA so that the

letters on the cartridge and those on the G3PA are in the same
direction and side A and side B are even.

Side A

Side B

4. Attach the terminal cover.

5. Switch on the power and check the G3PA to be sure it works

properly.

G32A-A40

The Power Device Cartridge is secured with screws.
Extraction

1. Switch off the power.

2. Remove the terminal cover.

3. Loosen and remove the two middle screws. These screws

are connected to terminals 1 and 2. (For safety reasons, be
sure to turn the power supply off.)

Loosen

Loosen

4. Loosen the screws in the corners.

Loosen

Loosen

5. Hold the indented parts on both sides of the cartridge and pull

up on the cartridge to remove it.

Mounting
Follow the procedures below to mount the Power Device Cartridge
on the G3PA.

1. Apply silicone grease to the entire surface of the heat radiator.

Apply silicone grease here.

2. Make sure that there is no dust or pieces of wire on the heat

radiator of the G32A-A or the G3PA-240B.

3. Insert the cartridge into the opening of the G3PA-240B.

(Insert until side A and side B are even.)

Side A

Side B

4. Tighten the screws in the corners. (Tightening torque: 0.59 to

0.78 N

S

m)

5. Tighten the middle screws. (Tightening torque: 0.59 to 0.78

N

S

m)

6. Attach the terminal cover.
7. Switch on the power and check the G3PA to be sure it works

properly.

Summary of Contents for G3PA-210B-VD

Page 1: ...pplicable output load Rated input voltage G3PA 210B VD Phototriac l Yes Yes 10 A at 24 to 240 VAC 5 to 24 VDC G3PA 220B VD o o ac coupler es es 20 A at 24 to 240 VAC 5 o C G3PA 240B VD 40 A at 24 to 2...

Page 2: ...2 DC12 24 G3PA 450B VD 2 DC12 24 Other Units Order Separately Units that Enable 2 line Switching of 3 phase Power Name Current flow Model Applicable SSR Short circuit Unit 10 A G32A D20 G3PA 210B VD...

Page 3: ...x DC Input B models 1 1 2 of load power source cycle 1 ms max AC Input 1 ms max BL models Release time 1 2 of load power source cycle 1 ms max DC Input 1 1 2 of load power source cycle 1 ms max AC Inp...

Page 4: ...0B L VD G3PA 210B L VD 25 15 G3PA 210B L VD G3PA 220B L VD Panel Ground 40 60 80 100 20 0 20 30 60 40 25 20 80 Ambient temperature C Ambient temperature C Load current A Load current A G3PA 430B VD G3...

Page 5: ...rature C Ambient temperature C Ambient temperature C Load current A Load current A Load current A 40 60 80 100 20 0 20 30 G3PA 240B L VD G3PA 260B L VD 60 40 42 20 G3PA 220B L VD G3PA 210B L VD 3 5 11...

Page 6: ...VD G3PA 260B L VD 64 40 48 20 G3PA 220B VD G3PA 210B VD 18 4 5 36 15 13 20 30 5 7 40 45 30 20 10 14 G3PA 210B L VD G3PA 220B L VD DIN track Panel Ground Ambient temperature C Ambient temperature C Loa...

Page 7: ...ly G3PA 210B L VD G3PA 220B L VD G3PA 240B L VD 260B L VD Inrush current A Peak Energizing time ms Inrush current A Peak Energizing time ms Inrush current A Peak Energizing time ms G3PA 430B VD G3PA 4...

Page 8: ...3PA 210B VD 220B VD models only Operation indicator Temperature indicator Linking terminal except for G3PA 260B VD Heat sink DIN track mounting part G3PA 220B VD Mounting hole Protective cover Power D...

Page 9: ...ad voltage Model Applicable SSR Conforms to VDE Power Device C t id 10 A 19 to 264 VAC G32A A10 VD DC5 24 G3PA 210B VD DC5 24 Yes o e e ce Cartridge 0 9 o 6 C G32A A10L VD DC5 24 G3PA 210BL VD DC5 24...

Page 10: ...ridge for replacement with a new one Extraction Follow the procedures below to dismount the Power Device Car tridge from the G3PA 1 Switch off the power 2 Remove the terminal cover 3 Hook the indented...

Page 11: ...h on the power and check the G3PA to be sure it works properly G32A A40 The Power Device Cartridge is secured with screws Extraction 1 Switch off the power 2 Remove the terminal cover 3 Loosen and rem...

Page 12: ...ners Loosen Loosen 5 Hold the indented part of both the corners to dismount the cartridge Mounting 1 Apply silicone grease to the entire surface of the heat radiator Apply silicone grease here 2 Make...

Page 13: ...wn 2 Insert the linking termi nal securely into the center of the screw and tighten the screw En sure that the linking terminal does not pro trude SSR G32A Unit SSR G32A Unit The cover will not fit if...

Page 14: ...g of up to three G3PA SSRs is possible Load current should be reduced by 10 for G3PA 210B VD 220B VD 240B VD and by 20 for other models To close mount more than three G3PA keep a distance of 10 mm bet...

Page 15: ...ise indicated G3PA 210B VD Terminal Arrangement Internal Connections Mounting Holes Without Terminal Cover With Terminal Cover Linking terminal B1 Linking terminal B2 4 6 dia 4 6 x 5 6 elliptical hole...

Page 16: ...Arrangement Internal Connections Mounting Holes Without Terminal Cover With Terminal Cover Linking terminal B1 Linking terminal B2 4 6 dia 4 6 x 5 6 elliptical hole Two 4 5 dia or M4 holes Trigger cir...

Page 17: ...Arrangement Internal Connections Mounting Holes Without Terminal Cover With Terminal Cover Linking terminal B1 Linking terminal B2 4 6 dia 4 6 x 5 6 elliptical hole Trigger circuit Input circuit Two 4...

Page 18: ...3PA 450B VD 2 Terminal Arrangement Internal Connections Mounting Holes Without Terminal Cover With Terminal Cover 4 6 x 5 6 elliptical hole 4 6 dia Two 4 5 dia or M4 holes Trigger circuit Input circui...

Page 19: ...Terminal Arrangement Internal Connections Mounting Holes 90 0 3 Two 4 5 dia or M4 25 0 3 Trigger circuit Input circuit 89 91 4 5 80 38 13 18 13 7 6 67 4 6 dia 100 max 47 max 4 6 x 5 6 elliptic hole 10...

Page 20: ...G3PA VD G3PA VD 151 ALL DIMENSIONS SHOWN ARE IN MILLIMETERS To convert millimeters into inches multiply by 0 03937 To convert grams into ounces multiply by 0 03527 Cat No K094 E1 3B...

Reviews: