Operation
Renewal Parts
G32A-A Power Device Cartridge
The G32A-A Power Device Cartridge (a Triac Unit) can be replaced with a new one. When the temperature indicator has changed from pink to
red, the triac circuitry may have malfunctioned possibly by an excessive flow of current, in which case, dismount the damaged cartridge for
replacement.
The damaged cartridge can be replaced with a new one without disconnecting the wires from the G3PA.
Improve the heat radiation efficiency of the G3PA before replacing the cartridge.
The G32A-A Power Device Cartridge can withstand an excessive current for a short period of time, such as may be caused accidentally by the
short circuitry of the load, in which case the temperature indicator will not turn red.
Appearance
G32A-A10-VD
G32A-A20-VD
G32A-A40-VD
G32A-A60-VD
G32A-A420-VD
G32A-A430-VD
G32A-A10
G32A-A20
G32A-A40
Replacement Parts
Name
Carry
current
Load voltage
Model
Applicable SSR
Conforms to
VDE
Power Device
C
t id
10 A
19 to 264 VAC
G32A-A10-VD DC5-24
G3PA-210B-VD DC5-24
Yes
o e
e ce
Cartridge
0
9 o 6
C
G32A-A10L-VD DC5-24
G3PA-210BL-VD DC5-24
es
G32A-A10-VD AC24
G3PA-210B-VD AC24
20 A
G32A-A20-VD DC5-24
G3PA-220B-VD DC5-24
0
G32A-A20L-VD DC5-24
G3PA-220BL-VD DC5-24
G32A-A20-VD AC24
G3PA-220B-VD AC24
40 A
G32A-A40-VD DC5-24
G3PA-240B-VD DC5-24
0
G32A-A40L-VD DC5-24
G3PA-240BL-VD DC5-24
G32A-A40-VD AC24
G3PA-240B-VD AC24
60 A
G32A-A60-VD DC5-24
G3PA-260B-VD DC5-24
60
G32A-A60L-VD DC5-24
G3PA-260BL-VD DC5-24
G32A-A60-VD AC24
G3PA-260B-VD AC24
20 A
150 to 440 VAC
G32A-A420-VD DC12-24
G3PA-420B-VD DC12-24
30 A
50 o
0
C
G32A-A430-VD DC12-24
G3PA-430B-VD DC12-24
20 A
180 to 528 VAC
G32A-A420-VD-2 DC12-24
G3PA-420B-VD-2 DC12-24
30 A
80 o 5 8
C
G32A-A430-VD-2 DC12-24
G3PA-430B-VD-2 DC12-24
50 A
G32A-A450-VD-2 DC12-24
G3PA-450B-VD-2 DC12-24
10 A
75 to 264 VAC
G32A-A10
G3PA-210B DC5-24
No
20 A
5 o 6
C
G32A-A20
G3PA-220B DC5-24
o
40 A
G32A-A40
G3PA-240B DC5-24
20 A
180 to 528 VAC
G32A-A420
G3PA-420B DC5-24
30 A
80 o 5 8
C
G32A-A430
G3PA-430B DC5-24