background image

7

F3SP-T01

Dimensions

(Unit: mm)

Relay contact output terminals

180

Two, 4.2 dia. holes

55

(169)

51

(40)

I/O terminals

Status indicators (LEDs)
From left to right: PWR, RY1 (K1), RY2 (K2), TEST, RESET, and AUX.

G7SA-3A1B (K1)

G7SA-3A1B (K2)

Modular Connector 
for Light Curtain 
Support Software

F3SP-T01

Summary of Contents for F3SP-T01

Page 1: ...or All Safety Sensors Type Applicable models Model Safety Terminal Relay F3SJ A P F3SP T01 Type Model Cable for connecting Support Software cable length 1 5 m E39 Z12 1 Replacement Relay G7SA 3A1B Rat...

Page 2: ...G AUX V G 1 2 3 4 13 14 23 24 NC NC 23 24 33 34 43 44 43 44 11 12 11 12 Receiver Emitter L1 Muting input 1 White L2 24 V Brown L3 Test input Green L4 Reset input Yellow L5 Communications line Gray L6...

Page 3: ...e mounted to the F3SJ 2 If a lockout reset is required connect a switch between RST and V Connecting Four Muting Sensors Note If you are connecting four muting sensors connect the sensor outputs to MA...

Page 4: ...4 V Brown Control output 2 White 0 V Blue External device monitoring input Red Control output 1 Green Shield Communications line Gray Auxiliary output Yellow Communications line Pink Note If a lockout...

Page 5: ...utput Muting output Muting Sensor 1 Muting Sensor 2 Muting Sensor 3 Muting Sensor 4 Connecting Four Muting Sensors Note If you are connecting four muting sensors connect the sensor outputs to MA1 MA2...

Page 6: ...ld Communications line Gray Reset input Yellow Communications line Pink 24 V Brown Control output 2 White 0 V Blue External device monitoring input Red Control output 1 Green Shield Communications lin...

Page 7: ...ntact output terminals 180 Two 4 2 dia holes 55 169 51 40 I O terminals Status indicators LEDs From left to right PWR RY1 K1 RY2 K2 TEST RESET and AUX G7SA 3A1B K1 G7SA 3A1B K2 Modular Connector for L...

Page 8: ...ater oil or chemicals Locations subject to dust including iron dust or salts Take appropriate and sufficient countermeasures when using the product in the following locations Locations subject to stat...

Page 9: ...m the DIN Track Secure both ends of the Safety Terminal Relays with End Plates The following products are sold separately Selecting the Power Supply Use the rated power supply voltage Do not use power...

Page 10: ...products Outdoor use uses involving potential chemical contamination or electrical interference or conditions or uses not described in this catalog Nuclear energy control systems combustion systems r...