5
F3SG-RR
Quick Installation Manual
5-3. EDM enabled, Auto Reset Mode, External Test in 0 V Active (not used),
Muting disabled and NPN Outputs
5-4. EDM disabled, Manual Reset Mode, External Test in 0 V Active(used),
Muting disabled and NPN Outputs
KM1, KM2: Safety relay with forcibly guided contacts (G7SA)
M: 3-phase motor
Not used (Pink)
Not used (Red) *5
Not used (White) *5
Not used (Yellow) *5
TEST (Black) *2
Not used (Gray)
+24 VDC (Brown)
+24 VDC (Brown)
RESET (Red) *3
OSSD 1 (Black)
OSSD 2 (White)
AUX (Yellow)
PC COM (+) (Gray) *4
PC COM (-) (Pink) *4
0 VDC (Blue)
0 VDC (Blue)
F39-JD
□□
A-L *6
F39-JD
□□
A-D *6
KM1
KM2
M
KM1 KM2
KM1
KM2
+24 VDC
Power Supply
0 VDC
Emitter
Receiver
*1. The functions are configurable with Configuration Tool. Refer to
Safety Light Curtain Configuration Tool for Model F3SG (SD
Manager 2) User’s Manual
for more information on setting the functions by the Configuration Tool.
*2. Connect the line to 0 V via a test switch (N.O. contact) if External Test is used.
*3. Connect a lockout reset switch (N.C. contact) to this line in series with the KM1 and KM2 if Lockout Reset is used.
*4. Used as MUTE A and B lines when Muting is used.
*5. The F39-JD
□
RA-L Single-Ended Cable for Emitter (Oil-Resistant Extension Cable) does not have the red, white and yellow wires.
*6. For the F39-JD
□
A-
□
Single-Ended Cable, connect the shield line to 0 V.
[Settings]
Function
Receiver
EDM Enabled (factory default setting) *1
Auto Reset (factory default setting) *1
NPN *1
Emitter
External Test: 0 V Active (End Cap:
White)
S1: Test Switch (Connect the line to 24 V if this switch is not required)
S2: Lockout/Interlock Reset Switch
KM1, KM2: Safety relay with forcibly guided contacts (G7SA)
M: 3-phase motor
S2
Not used (Pink)
Not used (Red) *4
Not used (White) *4
Not used (Yellow) *4
TEST (Black)
Not used (Gray)
+24 VDC (Brown)
+24 VDC (Brown)
RESET (Red) *1
OSSD 1 (Black)
OSSD 2 (White)
AUX (Yellow)
PC COM (+)(Gray)*3
PC COM (-)(Pink) *3
0 VDC (Blue)
0 VDC (Blue)
F39-JD
□□
A-L *5
F39-JD
□□
A-D *5
KM1
KM2
M
KM1 KM2
S1
Power Supply
+24 VDC
0 VDC
Emitter
Receiver
*1. Also used as EDM line.
*2. The functions are configurable with Configuration Tool. Refer to
Safety Light Curtain Configuration Tool for Model F3SG (SD
Manager 2) User’s Manual
for more information on setting the functions by the Configuration Tool.
*3. Used as MUTE A and B lines when Muting is used.
*4. The F39-JD
□
RA-L Single-Ended Cable for Emitter (Oil-Resistant Extension Cable) does not have the red, white and yellow wires.
*5. For the F39-JD
□
A-
□
Single-Ended Cable, connect the shield line to 0 V.
[Settings]
Function
Receiver
EDM Disabled *2
Manual Reset *2
NPN *2
Emitter
External Test: 0 V Active (End Cap:
White)
Mounting/Beam Alignment
Wiring
Setting
Operation check