1
F3SG-RR
Quick Installation Manual
Introduction
Thank you for purchasing the F3SG-
RR Series Safety Light Curtain (hereinafter referred to as the "F3SG-
RR"). This document contains simple instructions to install the F3SG-RR.
Please download the F3SG-RR User's Manual for full contents of the instructions from our website at:
http://www.ia.omron.com/f3sg-r
Table of Contents
1. What is Included................................................................................................................................1
2. System Components .........................................................................................................................2
3. F3SG-RR Setup Procedure Example................................................................................................2
4. Setting with Rotary Switch/End Cap..................................................................................................3
5.Wiring Examples ................................................................................................................................4
5-1. EDM enabled, Auto Reset Mode, External Test in 24 V Active (not used), Muting disabled and PNP Outputs.4
5-2. EDM disabled, Manual Reset Mode, External Test in 24 V Active(used), Muting disabled and PNP Outputs...4
5-3. EDM enabled, Auto Reset Mode, External Test in 0 V Active (not used), Muting disabled and NPN Outputs...5
5-4. EDM disabled, Manual Reset Mode, External Test in 0 V Active(used), Muting disabled and NPN Outputs.....5
6-1. Mounting with Free-Location Brackets (F39-LGRA) .................................................................6
6-2. Mounting with Top/Bottom Brackets (F39-LGRTB)...................................................................8
6-3. Mounting with Top/Bottom Brackets (F39-LGRTB-2) ...............................................................9
6-4. Mounting with Top/Bottom Brackets (F39-LGRTB-3) .............................................................10
1. What is Included
For ratings/specifications, input/output circuit, LED indicator status and troubleshooting, refer to
Safety Light Curtain F3SG-RR
Series User's Manual
.
Product
Quantity
F3SG-
RR
main unit
Emitter x 1, Receiver x 1
Refer to
F3SG-RR Series User's Manual
for more information.
End Cap (for External Test Input Selection)
(Color: White)
1
Warning Zone Label
1
Troubleshooting Guide Sticker
1
Safety Precautions
3
Quick Installation Manual
1
Factory Default Settings
Feature
Factory Default Setting
External Test
24 V Active
Interlock
Auto Reset Mode enabled
EDM (External Device Monitoring)
Enabled
Auxiliary Output
Safety output information
(Inverted signal output: Enable)
Muting
Disabled
Override
Disabled