4
F3SG-RR
Quick Installation Manual
5.Wiring Examples
For input/output circuit and other examples than below, refer to
Safety Light Curtain F3SG-RR Series User's Manual
.
5-1. EDM enabled, Auto Reset Mode, External Test in 24 V Active (not
used), Muting disabled and PNP Outputs
5-2. EDM disabled, Manual Reset Mode, External Test in 24 V Active(used),
Muting disabled and PNP Outputs
KM1, KM2: Safety relay with forcibly guided contacts (G7SA)
M: 3-phase motor
+24 VDC (Brown)
Not used (Yellow) *5
TEST (Black) *2
Not used (White) *5
Not used (Red) *5
Not used (Pink)
Not used (Gray)
0 VDC (Blue)
OSSD 1 (Black)
OSSD 2 (White)
+24 VDC (Brown)
0 VDC (Blue)
AUX (Yellow)
PC COM (-) (Pink) *4
PC COM (+) (Gray) *4
RESET (Red) *3
F39-JD
□□
A-L
*6
F39-JD
□□
A-D *6
KM1
KM2
M
KM1 KM2
KM1
KM2
Power Supply
+24 VDC
0 VDC
Receiver
Emitter
*1. The functions are configurable with Configuration Tool. Refer to
Safety Light Curtain Configuration Tool for Model F3SG (SD
Manager 2) User’s Manual
for more information on setting the functions by the Configuration Tool.
*2. Connect the line to 24 V via a test switch (N.O. contact) if External Test is used.
*3. Connect a lockout reset switch (N.C. contact) to this line in series with the KM1 and KM2 if Lockout Reset is used.
*4. Used as MUTE A and B lines when Muting is used.
*5. The F39-JD
□
RA-L Single-Ended Cable for Emitter (Oil-Resistant Extension Cable) does not have the red, white and yellow wires.
*6. For the F39-JD
□
A-
□
Single-Ended Cable, connect the shield line to 0 V.
[Settings]
Function
Receiver
EDM Enabled (factory default setting) *1
Auto Reset (factory default setting) *1
PNP (factory default setting) *1
Emitter
External Test: 24 V Active (End Cap:
Black) (factory default setting)
S1: Test Switch (Connect the line to 0 V if this switch is not required)
S2: Lockout/Interlock Reset Switch
KM1, KM2: Safety relay with forcibly guided contacts (G7SA)
M: 3-phase motor
S2
KM1
KM2
M
KM1 KM2
S1
+24 VDC (Brown)
Not used (Yellow) *4
TEST (Black)
Not used (White) *4
Not used (Red) *4
Not used (Pink)
Not used (Gray)
0 VDC (Blue)
OSSD 1 (Black)
OSSD 2 (White)
+24 VDC (Brown)
0 VDC (Blue)
AUX (Yellow)
PC COM (-) (Pink) *3
PC COM (+) (Gray) *3
RESET (Red) *1
F39-JD
□□
A-L *5
F39-JD
□□
A-D *5
Power Supply
+24 VDC
0 VDC
Receiver
Emitter
*1. Also used as EDM line.
*2. The functions are configurable with Configuration Tool. Refer to
Safety Light Curtain Configuration Tool for Model F3SG (SD
Manager 2) User’s Manual
for more information on setting the functions by the Configuration Tool.
*3. Used as MUTE A and B lines when Muting is used.
*4. The F39-JD
□
RA-L Single-Ended Cable for Emitter (Oil-Resistant Extension Cable) does not have the red, white and yellow wires.
*5. For the F39-JD
□
A-
□
Single-Ended Cable, connect the shield line to 0 V.
[Settings]
Function
Receiver
EDM Disabled *2
Manual Reset *2
PNP (factory default setting) *2
Emitter
External Test: 24 V Active (End Cap:
Black) (factory default setting)
Mounting/Beam Alignment
Wiring
Setting
Operation check