F3SG-RA
1
1
Connections (Basic Wiring Diagram)
Standalone F3SG-RA using PNP Outputs
The following is the example of External Device Monitoring enabled, Manual Reset mode, PNP output and External Test in 24
V
Active.
DIP Switch settings *2
: Indicates a switch position.
Configure functions with the DIP Switches before wiring.
Wiring Example
Note:
The wiring examples in later pages do not indicate functional earth. To use functional earth, wire an earth cable according to the example
above. Refer to
Safety Light Curtain F3SG-R Series User's Manual
for more information.
Function
DIP-SW1
DIP-SW2
Receiver
EDM Enabled
Manual Reset
PNP (factory default setting)
Emitter
External Test: 24
V
Active (factory default setting)
2
O
N
2
O
N
3
O
N
3
O
N
4
O
N
4
O
N
7
O
N
7
O
N
4
O
N
OSSD1 : Black
OSSD2 : White
24 VDC : Bro
w
n
N
ot
u
sed : Yello
w
TEST : Black
N
ot
u
sed : White
24 VDC : Bro
w
n
0 VDC : Bl
u
e
Recei
v
er
Emitter
0 VDC : Bl
u
e
AUX : Red
MUTE B : Pink
MUTE A : Gray
RESET : Yello
w
*1
S2
S1: Test S
w
itch (Connect the line to 0 V
if this s
w
itch is not re
qu
ired)
S2: Locko
u
t/Interlock Reset S
w
itch
KM1, KM2: Safety relay
w
ith forci
b
ly g
u
ided contacts (G7SA)
or magnetic contactor
M: 3-phase motor
S1
F39-JG
@
A-L
F39-JG
@
A-D
KM1
KM2
KM1
KM2
Po
w
er S
u
pply
+24 VDC
0 VDC
KM1
KM2
M
Un
b
locked
Blocked
Test S
w
itch (S1)
Beam state
Reset S
w
itch (S2)
OSSD
F
u
nctional Earth
*1.Also used as EDM input line.
*2.The functions are configurable with DIP Switch. Refer to
Safety Light Curtain F3SG-R Series User's Manual
for more
information on setting the functions by the DIP Switch.