F3SG-RA
1
0
Indicator
Emitter
Receiver
Interface Unit
Lamp
Name of Indicator
Color
Illuminated
Blinking
Test
TEST
Green
−
External Test is being performed
Operating range
LONG
Green
Long range mode is selected
Lockout state due to DIP Switch setting error
or Operating range selection setting error
Power
PO
W
ER
Green
Power is ON.
Error due to noise
Lockout
LOCKOUT
Red
−
Lockout state due to error in emitter
Name of Indicator
Color
Illuminated
Blinking
Top-beam-state
TOP
Blue
The top beam is unblocked
Muting/Override state, or Lockout state due to Cap
error or Other sensor error
PNP/NPN mode
NPN
Green
NPN mode is selected by DIP Switch
−
Response time
SLO
W
Green
Response Time Adjustment is enabled
−
Sequence error
SEQ
Yellow
−
Sequence error in Muting or Pre-reset mode
Blanking
BLANK
Green
Blanking,
W
arning Zone or Reduced Resolution is
enabled
Teach-in mode, or Blanking Monitoring error
Configuration
CFG
Green
−
Teach-in mode, zone measurement beng performed
by Dynamic Muting, or Lockout state due to
Parameter error or Cascading Configuration error
Interlock
INT-LK
Yellow
Interlock state
Pre-reset mode
External device
monitoring
EDM
Green
RESET input is in ON state
Lockout state due to EDM error
Internal error
INTERNAL
Red
−
Lockout state due to Internal error, or error due
to abnormal power supply or noise
Lockout
LOCKOUT
Red
−
Lockout state due to error in receiver
Stable-state
STB
Green
Incident light level is 170% or higher of ON-threshold
Safety output is instantaneously turned OFF due to
ambient light or vibration
ON/OFF
ON/OFF
Green
Safety output is in ON state
−
Red
Safety output is in OFF state, or the sensor is in
Setting state
Lockout state due to Safety Output error, or error due
to abnormal power supply or noise
Communication
COM
Green
Synchronization between emitter and receiver is
maintained
Lockout state due to Communication error, or error
due to abnormal power supply or noise
Bottom-beam-state
BTM
Blue
The bottom beam is unblocked
Muting/Override state, or Lockout state due to DIP
Switch setting error
Main unit
PC/AT compatible machine (computer that runs Microsoft
W
indows)
Operating system (OS)
W
indows 7 (32-bit/64-bit),
W
indows 8 (32-bit/64-bit)
Communication port
USB port
×
1
Ambient temperature
Operating: -10 to 55
°
C, Storage: -30 to 70
°
C(non-icing and non-condensing)
Ambient humidity
Operating: 35% to 85%, Storage: 35% to 95%(non-condensing)
Item
F39-LP
Applicable Sensor
F3SG-
@
RA Series Safety Light Curtain (Receiver)
LED Light Color
Red/Green/Orange
Power Supply Voltage
24
V
DC
±
20%, ripple p-p 10% max.(shares sensor
′
s power supply)
Current Consumption
25 mA max. (shares sensor
′
s power supply.)
Ambient Temperature
Operating: -10 to 55
°
C, Storage: -25 to 70
°
C
Ambient Humidity
Operating: 35% to 85%, Storage: 35% to 95%
Vibration Resistance
10 to 55 Hz, Multiple amplitude of 0.7 mm,20 sweeps for all 3 axes
Shock Resistance
100 m/s
2
, 1000 shocks for all 3 axes
Degree of Protection
IP65 and IP67(
W
hen attached to F3SG)
Type of Connection
Connectable to F3SG-RA
′
s terminal connector
Material
Lighting element: PC, Other body parts: PBT
Weight
45 g (when packaged)