F3SG-RA
2
1
Standalone F3SG-RA with Y-Joint Plug/Socket Connector using PNP outputs
The following is the example of External Device Monitoring enabled, Manual Reset mode, PNP output and External Test in 24
V
Active.
DIP Switch settings *3
: Indicates a switch position.
Configure functions with the DIP Switches before wiring.
Wiring Example
Function
DIP-SW1
DIP-SW2
Receiver
EDM Enabled
Manual Reset
PNP (factory default setting)
Emitter
External Test: 24
V
Active (factory default setting)
2
O
N
2
O
N
3
O
N
3
O
N
4
O
N
4
O
N
7
O
N
7
O
N
4
O
N
KM1
KM2
M
0 VDC: Bl
u
e
RESET:
Yello
w
*1
MU
TE A: Gray
MUTE B: Pink
AUX: Red
OSSD1: Black
OSSD2: White
24 VDC
: Bro
w
n
+24 VDC
0 VDC
Po
w
er s
u
pply
I
N
PLC *2
KM1
KM2
F39-JG
@
B-L
F39-GC
N
Y2
F39-JG
@
A-D
S1
KM1
KM2
S1: Locko
u
t/Interlock Reset S
w
itch
KM1,KM2: External de
v
ice feed
b
ack
M: 3-phase motor
PLC: Programma
b
le controller
(Used for monitoring only.
N
OT related to safety system.)
Un
b
locked
Blocked
Beam state
Reset S
w
itch (S1)
OSSD
Recei
v
er
Emitter
*1.Also used as EDM input line.
*2.
W
hen connecting to the PLC, the output mode must be
changed with the Configuration Tool.
*3.The functions are configurable with DIP Switch. Refer to
Safety Light Curtain F3SG-R Series User's Manual
for more
information on setting the functions by the DIP Switch.