5-3
5-1 DIP switch setting - Overview
F3EM2 MEASURING LIGHT CURTAINS OPERATION MANUAL
5
Operating serial output models (RS-
Dip-switch setting receiver:
There are two lines of dip switches in each transmitter and receiver. The settings must
be done for both lines.
Dip-SW
Status
Function
1
OFF
Optical Synch (default)
ON
Wire synch
2+3
RS baud rate for serial operation
2
3
Speed
OFF
OFF
9600bps (default)
OFF
ON
19200bps
ON
OFF
38400bps
ON
ON
76800bps
4+5
Interrogation byte for serial operation
4
5
Hexadecimal code /
binary code
Analogue output
OFF
OFF
FAh
11111010 (default)
0-10V (default)
OFF
ON
FBh / 11111011
0-10V
ON
OFF
FCh / 11111100
10-0V
ON
ON
FDh /11111101
10-0V
6+7+8
Output function
6
7
8
Serial output
Analogue output
OFF
OFF
OFF
Bitmap of optics (default) NAB
(default)
OFF
OFF
ON
FBB + NBB (4 byte total)
NAB
OFF
ON
OFF
FBM + NAB (4 byte total)
LBB
OFF
ON
ON
LBB + NBB (4 byte total)
NBB
ON
OFF
OFF
LBM + NAB (4 byte total)
FBB
ON
OFF
ON
Continuous bitmap
transmission
disabled
ON
ON
OFF
FBB + LBB (4 byte total)
NBB
ON
ON
ON
Holes detection
disabled
Summary of Contents for F3EM2 Series
Page 4: ......
Page 6: ...4...
Page 10: ......
Page 18: ......
Page 22: ......
Page 26: ......
Page 35: ...F3EM2 MEASURING LIGHT CURTAINS OPERATION MANUAL 6 Order codes...
Page 37: ...F3EM2 MEASURING LIGHT CURTAINS OPERATION MANUAL 7 7 1 Ratings 7 2 Technical specifications...
Page 43: ...F3EM2 MEASURING LIGHT CURTAINS OPERATION MANUAL 9 Dimensions...