5-6
5-4 Communication protocol for serial output
F3EM2 MEASURING LIGHT CURTAINS OPERATION MANUAL
5
Operating serial
output models
Bit signal vs. beam status is:
0 = BEAM NOT INTERUPTED
1 = BEAM INTERRUPTED
FBB + NBB
Dip switch setting:
The reply received from the light curtain is composed of 4 bytes.
The first two bytes are related to FBB data
The second two bytes are related to NBB.
FBB data is the binary conversion of the FBB id number.
NBB data is the binary conversion of the NBB number.
Example of the response protocol of a light curtain with 9 beams and FBB + NBB settings:
FBB = 4, NBB = 4 (HEX FORMAT)
H = high order byte
L = low order byte
FBM + NAB
Dip switch setting:
The reply received from the light curtain is composed of 4 bytes.
The first two bytes are related to FBM data
The second two bytes are related to NAB.
FBM data is the binary conversion of the FBM id number.
NAB data is the binary conversion of the NAB number.
The order of bytes in the protocol is same as example described for FBB + NBB setting.
6
7
8
Type of function
OFF
OFF
ON
FBB + NBB
1
st
byte H
FBB
0
0
0
0
0
0
0
0
2
nd
byte L
FBB
0
0
0
0
0
1
0
0
3
rd
byte H
NBB
0
0
0
0
0
0
0
0
4
th
byte L
NBB
0
0
0
0
0
1
0
0
6
7
8
Type of function
OFF
ON
OFF
FBM + NAB
NBB
FBB
1
9
Summary of Contents for F3EM2 Series
Page 4: ......
Page 6: ...4...
Page 10: ......
Page 18: ......
Page 22: ......
Page 26: ......
Page 35: ...F3EM2 MEASURING LIGHT CURTAINS OPERATION MANUAL 6 Order codes...
Page 37: ...F3EM2 MEASURING LIGHT CURTAINS OPERATION MANUAL 7 7 1 Ratings 7 2 Technical specifications...
Page 43: ...F3EM2 MEASURING LIGHT CURTAINS OPERATION MANUAL 9 Dimensions...