2-3
2-2 Mechanical installation
F3EM2 MEASURING LIGHT CURTAINS OPERATION MANUAL
2
Installation
2-2 Mechanical installation
Mounting accessories
The F3EM2 system is mechanically installed by using the T-slots on the two sides or the back-
side of the housing.
Use the movable bolts, washers, growers and nuts to fix the mounting brackets as shown in
the picture
Note: Shipment contains different quantity of brackets, depending on the length of the SLC. Longer SLC
contains a higher number of brackets, following the rule of every 400 mm one bracket.
Additional mounting rigidity
It is recommended that the distance between the mounting brackets is 400 mm or less for
optimum performance of the F3EM2 system.
ID
Description
1
movable M6 bolt
2
fixing braket
3
M6 washer
4
M6 Grower
5
M6 nut