Photoelectric Sensors

Safety Precautions

Note: In addition to the following precautions, please read and observe the common precautions for the instructions included with the product.

Precautions for Correct Use

Amplifier Unit

Installation

• Operation after Turning Power ON

The Amplifier Unit is ready to operate within 200 ms after the power 
supply is turned ON. If the Sensor and load are connected to power 
supplies separately, be sure to turn ON the power supply to the Sen-
sor first.

Mounting

• Connecting and Disconnecting Connectors

Mounting Connectors

1. Insert the Master or Slave Connector into the Amplifier Unit until it 

clicks into place.

2. Attach the protector seals (provided as accessories) to the sides 

of master and slave connectors that are not connected.

Note: Attach the seals to the sides with grooves

Removing Connectors

1. Slide the slave Amplifier Unit(s) for which the Connector is to be 

removed away from the rest of the group.

2. After the Amplifier Unit(s) has been separated, press down on the 

lever on the Connector and remove it. (Do not attempt to remove 
Connectors without separating them from other Amplifier Units 
first.)

• Joining and Removing Amplifier Units

Joining Amplifier Units

1. Mount the Amplifier Units one at a time onto the DIN track.

2. Slide the Amplifier Units together, line up the clips, and press the 

Amplifier Units together until they click into place.

Separating Amplifier Units
Slide Amplifier Units away from each other, and remove from the 
DIN track one at a time. (Do not attempt to remove Amplifier Units 
from the DIN track without separating them first.)

Note 1. The specifications for ambient temperature will vary accord-

ing to the number of Amplifier Units used together. For de-
tails, refer to Ratings/Characteristics.

2. Always turn OFF the power supply before joining or separat-

ing Amplifier Units.

• Mounting the End Plate (PFP-M)

An End Plate should be used if there is a possibility of the Amplifier 
Unit moving, e.g., due to vibration. If a Mobile Console is going to be 
mounted, connect the End Plate in the direction shown in the follow-
ing diagram.

• Mounting the Mobile Console Head

Leave a gap of at least 20 mm between the nearest Amplifier Unit 
and the Mobile Console head.

Insert

Seal

Seal

Press down

Remove

Lever

Click into place

End Plate

20 mm

Summary of Contents for E3X-MDA11

Page 1: ...l from the Mobile Con sole The industry s first power tuning func tion in a digital amplifier Stable long term performance due to Omrons s APC function Two large easy to read displays The remarkable n...

Page 2: ...MDA Having problems gang mounting Fiber Sensor Amplifier Units in tight spaces 50 mm 100 mm Half the Space Incident level Operation indicator Channel 1 display Channel 2 display Incident level Operati...

Page 3: ...mm Remarkable space saving of approx 50 Power saving of approx 40 Savings per channel compared with existing products Detection and front back discrimination of parts Detection of bends in electronic...

Page 4: ...ir cuit is ON or OFF Time OMRON provides the industry s most stable long term detection by using new 4 element LEDs and an APC Auto Power Control circuit Time Without APC circuit Without APC circuit 3...

Page 5: ...output 2 channel models AND OR output E3X MDA11 E3X MDA41 Item Appearance Functions Model NPN output PNP output 2 channel models AND OR output E3X MDA6 E3X MDA8 Item Appearance Cable length No of con...

Page 6: ...from OFF delay ON delay or one shot timer 1 ms to 5 s 1 to 20 ms set in 1 ms increments 20 to 200 ms set in 10 ms increments 200 ms to 1 s set in 100 ms increments and 1 to 5 s set in 1 s increments A...

Page 7: ...nd Z directions Shock resistance destruction 500 m s2 for 3 times each in X Y and Z directions Enclosure rating IEC 60529 IP50 with Protective Cover attached Connection method Prewired cable Standard...

Page 8: ...tion indicator orange ON OFF Output transistor ON OFF Load relay Operate Release Between brown and black CH1 CH2 ON OFF ON OFF L ON D ON T T Incident light No incident light L ON D ON T T Incident lig...

Page 9: ...AND ON delay AND T T T One shot UP DOWN MODE Lock Button Locks the fiber Operation Keys Function setting operations Channel Selector Mode Selector Use to select SET or RUN mode ON when output is ON O...

Page 10: ...ximum sensitivity This method is ideal when using a Through beam Fiber Unit to detect workpieces so that detection is not influenced to any great degree by dust and other environmental factors Display...

Page 11: ...piece and the value between the two measured value can be set as the threshold UP DOWN RUN will be displayed With no workpiece The previous display will return when the setting has been completed The...

Page 12: ...rements of 100 Maximum power M Display orientation orientation To reverse the orientation of the display Up down reversed display Normal display 1 Light levels for channels 1 and 2 The incident light...

Page 13: ...N delay timer is selected the one shot timer is automati cally set i e the timer function cannot be selected Output for each channel Output when the output is ON for both channels 1 and 2 Output when...

Page 14: ...in To return to original value for incident light level Set the Mode Selector to RUN Factory setting 3 s Press together see note MODE MODE UP UP RUN OFF will flash twice and key operations will be ena...

Page 15: ...it Do not attempt to remove Connectors without separating them from other Amplifier Units first Joining and Removing Amplifier Units Joining Amplifier Units 1 Mount the Amplifier Units one at a time...

Page 16: ...to light from other sensors If this occurs decrease the sensitivity i e decrease the power or increase the threshold to perform stable detection EEPROM Writing Error If the data is not written to the...

Page 17: ...6 28 1 4 5 10 7 5 65 4 5 16 Two M3 E3X MDA11 E3X MDA41 Main display Sub display Vinyl insulated round cable Standard length 2 m Cable Specifications A 4 dia 2 conductor conductor cross sectional area...

Page 18: ...Diameters E3X CN11 3 conductors E3X CN21 4 conductors E3X CN22 2 conductors 4 0 mm dia E3X CN12 1 conductor 2 6 mm dia Connector Dia A 2 Hole for optical communications Mounting Holes First operation...

Page 19: ...ble conductor cross sectional area 0 2 mm2 insulation diameter 1 1 mm is used 136 50 52 8 22 Optical communications connection indicator Sensor operation indicator Main display Sub display RIGHT key E...

Page 20: ...erest of product improvement specifications are subject to change without notice Cat No E11E EN 01 OMRON EUROPE B V Wegalaan 67 69 NL 2132 JD Hoofddorf The Netherlands Phone 31 23 568 13 00 Fax 31 23...

Reviews: