6. Convenient Functions

6-1. Zeroing the Digital Display

The incident light level on the digital display can be set to 0.

Change the function to 0rst (zero reset) with the MODE key. The de-

fault setting is PTUN.

6-2. Locking the Keys

All key operations can be disabled.

Note: Press the DOWN or UP key right after pressing the MODE key.

6-3. Initializing Settings

All settings can be returned to their original default settings.

3 s

MODE

3 s

MODE

DOWN

MODE

RUN

To reset to 0 again:

To return to original value
for incident light level:

Set the Mode Selector  
to RUN

Factory setting

3 s

Press together (see note).

MODE

MODE

UP

UP

RUN

"OFF" will flash twice and
key operations will be
enabled.

To release the lock:

"ON" will flash twice and
key operations will be
disabled. 

LOC

ON

LOC

OFF

Set the Mode Selector  
to RUN.

Factory setting

* If a key is pressed while key operations are locked, "LOC" will flash

twice on the display to indicate that

key operations have been disabled.

3 s

Press together (see note).

3 s

Press together (see note).

MODE

MODE

UP

DOWN

SET

Settings initialized.

Operation canceled.

INIT

NO?

Set the Mode Selector  
to SET.

INIT

YES?

UP

DOWN

3 s

Press together (see note).

Summary of Contents for E3X-MDA11

Page 1: ...l from the Mobile Con sole The industry s first power tuning func tion in a digital amplifier Stable long term performance due to Omrons s APC function Two large easy to read displays The remarkable n...

Page 2: ...MDA Having problems gang mounting Fiber Sensor Amplifier Units in tight spaces 50 mm 100 mm Half the Space Incident level Operation indicator Channel 1 display Channel 2 display Incident level Operati...

Page 3: ...mm Remarkable space saving of approx 50 Power saving of approx 40 Savings per channel compared with existing products Detection and front back discrimination of parts Detection of bends in electronic...

Page 4: ...ir cuit is ON or OFF Time OMRON provides the industry s most stable long term detection by using new 4 element LEDs and an APC Auto Power Control circuit Time Without APC circuit Without APC circuit 3...

Page 5: ...output 2 channel models AND OR output E3X MDA11 E3X MDA41 Item Appearance Functions Model NPN output PNP output 2 channel models AND OR output E3X MDA6 E3X MDA8 Item Appearance Cable length No of con...

Page 6: ...from OFF delay ON delay or one shot timer 1 ms to 5 s 1 to 20 ms set in 1 ms increments 20 to 200 ms set in 10 ms increments 200 ms to 1 s set in 100 ms increments and 1 to 5 s set in 1 s increments A...

Page 7: ...nd Z directions Shock resistance destruction 500 m s2 for 3 times each in X Y and Z directions Enclosure rating IEC 60529 IP50 with Protective Cover attached Connection method Prewired cable Standard...

Page 8: ...tion indicator orange ON OFF Output transistor ON OFF Load relay Operate Release Between brown and black CH1 CH2 ON OFF ON OFF L ON D ON T T Incident light No incident light L ON D ON T T Incident lig...

Page 9: ...AND ON delay AND T T T One shot UP DOWN MODE Lock Button Locks the fiber Operation Keys Function setting operations Channel Selector Mode Selector Use to select SET or RUN mode ON when output is ON O...

Page 10: ...ximum sensitivity This method is ideal when using a Through beam Fiber Unit to detect workpieces so that detection is not influenced to any great degree by dust and other environmental factors Display...

Page 11: ...piece and the value between the two measured value can be set as the threshold UP DOWN RUN will be displayed With no workpiece The previous display will return when the setting has been completed The...

Page 12: ...rements of 100 Maximum power M Display orientation orientation To reverse the orientation of the display Up down reversed display Normal display 1 Light levels for channels 1 and 2 The incident light...

Page 13: ...N delay timer is selected the one shot timer is automati cally set i e the timer function cannot be selected Output for each channel Output when the output is ON for both channels 1 and 2 Output when...

Page 14: ...in To return to original value for incident light level Set the Mode Selector to RUN Factory setting 3 s Press together see note MODE MODE UP UP RUN OFF will flash twice and key operations will be ena...

Page 15: ...it Do not attempt to remove Connectors without separating them from other Amplifier Units first Joining and Removing Amplifier Units Joining Amplifier Units 1 Mount the Amplifier Units one at a time...

Page 16: ...to light from other sensors If this occurs decrease the sensitivity i e decrease the power or increase the threshold to perform stable detection EEPROM Writing Error If the data is not written to the...

Page 17: ...6 28 1 4 5 10 7 5 65 4 5 16 Two M3 E3X MDA11 E3X MDA41 Main display Sub display Vinyl insulated round cable Standard length 2 m Cable Specifications A 4 dia 2 conductor conductor cross sectional area...

Page 18: ...Diameters E3X CN11 3 conductors E3X CN21 4 conductors E3X CN22 2 conductors 4 0 mm dia E3X CN12 1 conductor 2 6 mm dia Connector Dia A 2 Hole for optical communications Mounting Holes First operation...

Page 19: ...ble conductor cross sectional area 0 2 mm2 insulation diameter 1 1 mm is used 136 50 52 8 22 Optical communications connection indicator Sensor operation indicator Main display Sub display RIGHT key E...

Page 20: ...erest of product improvement specifications are subject to change without notice Cat No E11E EN 01 OMRON EUROPE B V Wegalaan 67 69 NL 2132 JD Hoofddorf The Netherlands Phone 31 23 568 13 00 Fax 31 23...

Reviews: