E3X-DAC-S

10

Nomenclature

Safety Precautions

Refer to 

Warranty and Limitations of Liability

.

This product is not designed or rated for 

ensuring safety of persons either directly or 

indirectly.

Do not use it for such purposes.

Do not use the product with voltage in excess 

of the rated voltage. Excess voltage may result 

in malfunction or fire.

Never use the product with an AC power 

supply. 

Otherwise, explosion may result.

High-temperature environments may result in

burn injury.

The following precautions must be observed to ensure safe 

operation of the Sensor.

1.  Do not use the Sensor in an environment where explosive 

or flammable gas is present.

2.  Do not use the Sensor in a location subject to splattering 

of water, oils, or chemicals.

3.  Do not attempt to disassemble, repair, or modify the 

Sensor.

4.  Do not apply voltages or currents that exceed the rated 

range to the Sensor.

5.  Do not use the Sensor in an ambient atmosphere or 

environment that exceeds the ratings.

6. 

W

ire the power supply correctly, including the polarity.

7.  Connect the load correctly.

8

.  Do not short-circuit the load at both ends.

9.  Do not use the Sensor if the case is damaged.

10. Dispose of the Sensor as industrial waste.

11. Do not use the Sensor in locations subject to direct 

sunlight.

12. Burn injury may occur. The Sensor surface temperature 

rises depending on application conditions, such as the 

ambient temperature and the power supply voltage. Use 

caution when operating or performing maintenance on the 

Sensor.

Fiber Amplifier Units

Standard Models
E3X-DAC

@

-S (

@

: 11/41/6/8)

Advanced models with simultaneous 2-color determination 
E3X-DAC

@

-S (

@

: 21/51)

Advanced models with 4-color determination
E3X-DAC

@

B-S (

@

: 21/51)

ON 

w

hen o

u

tp

u

t is ON. 

OFF 

w

hen o

u

tp

u

t is OFF. 

Operation Indicator  

(orange) 

Locks the fi

b

er 

u

nit.

Lock le

v

er 

Incident le

v

el, f

u

nction, etc. 

Main Display (red) 

Threshold, f

u

nction settings, etc. 

S

ub

-display (green) 

Use to select SET 
or RUN mode. 

Mode Selector 

S

w

itch 

Lit orange: Operation 
in I Mode. 

I Mode Indicator 

F

u

nction setting operations 

Operation Keys 

Use to s

w

itch 

b

et

w

een Light ON 

and Dark ON modes. 

Operation Selector S

w

itch 

UP 

DOWN 

MODE 

Locks the fi

b

er 

u

nit.

Incident le

v

el, f

u

nction, etc. 

ON 

w

hen o

u

tp

u

t is ON. 

OFF 

w

hen o

u

tp

u

t is OFF. 

Ch1 Operation Indicator 

Lock le

v

er 

Main Display (red) 

Used to select the channel to 
display and set. 

Channel S

w

itch 

Use to select SET 
or RUN mode. 

Mode Selector S

w

itch 

ON 

w

hen o

u

tp

u

t is ON. 

OFF 

w

hen o

u

tp

u

t is OFF. 

Ch2 Operation Indicator 

F

u

nction setting operations 

Operation Keys 

Threshold, f

u

nction settings, etc. 

S

ub

-display (green) 

UP 

DOWN 

MODE 

WARNING

CAUTION

Precautions for Safe Use

Downloaded from

Arrow.com.

Downloaded from

Arrow.com.

Downloaded from

Arrow.com.

Downloaded from

Arrow.com.

Downloaded from

Arrow.com.

Downloaded from

Arrow.com.

Downloaded from

Arrow.com.

Downloaded from

Arrow.com.

Downloaded from

Arrow.com.

Downloaded from

Arrow.com.

Summary of Contents for E3X-DAC-S Series

Page 1: ...ee parameters RGB to enable stable detection even when the workpiece moves Not Affected by Move ment Intensity Detection Previous Type Color Detection Color Sensing Type Easy and Reliable Featuring a...

Page 2: ...X DAC41 S 2M Advanced models with simultaneous 2 color determination Standard models Simultaneous 2 color determination AND OR output Remote setting E3X DAC21 S 2M E3X DAC51 S 2M Advanced models with...

Page 3: ...for same color as registered color or ON for mismatch ON for different color from registered color Timer function Timer type OFF delay ON delay or one short Timer time 1 ms to 5 s variable Control out...

Page 4: ...ansistor NPN ON Shorted to 0 V sourcing current 1 mA max OFF Open or shorted to Vcc ON 1 5 V max sourcing current 1 mA max OFF Vcc 1 5 V to Vcc leakage current 0 1 mA max PNP ON Shorted to Vcc sinking...

Page 5: ...19 15 13 4 5 4 1 3 2 4 1 5 E32 D21 E32 D22B 8 8 6 7 5 8 2 1 1 8 1 3 1 1 0 7 E32 D25XB 14 10 9 3 3 2 1 1 7 1 1 Fluorine coating E32 D11U 42 32 26 11 8 5 6 5 3 5 Special beam models Long dis tance high...

Page 6: ...ating E32 T11U 190 140 120 60 40 28 24 20 Special beam models Long dis tance high power E32 T17L 4300 3200 2800 1400 900 600 500 460 E32 TC200 E39 F1 1100 850 700 360 220 160 140 120 E32 T11R E39 F1 1...

Page 7: ...00 E32 T61 S E39 F2 120 95 80 42 26 19 16 14 E32 T84S S 360 280 240 120 75 55 46 40 Chemical resistant E32 T11F 550 420 360 180 110 80 70 60 E32 T12F 850 650 550 280 180 120 100 95 E32 T14F 100 80 70...

Page 8: ...Red purple Black White Red Yellow red Yellow Yellow green Green Blue green Blue Blue purple Purple Red purple Black Number of colors differentiated combinations 0 20 40 60 80 100 120 140 0 Sensing di...

Page 9: ...24 VDC Display For the E3X DAC B S Match Mismatch ON OFF ON OFF Operate Reset Output transistor Between brown and black leads Operation indicator orange Load e g relay Between blue and black leads Ma...

Page 10: ...ding on application conditions such as the ambient temperature and the power supply voltage Use caution when operating or performing maintenance on the Sensor Fiber Amplifier Units Standard Models E3X...

Page 11: ...on the Connector and remove it Do not attempt to remove Connectors without separating them from other Amplifier Units first Adding and Removing Fiber Amplifier Units Adding Fiber Amplifier Units 1 Mo...

Page 12: ...plifier Units can be slid together and used in groups Do not however slide the Amplifier Units or attempt to remove any of the Amplifier Units during operation Others Protective Cover Always keep the...

Page 13: ...N End Plate sold separately PFP M Multiple connection diagram Two 2 4 dia DIN track mounting Fiber Attachment mounted E39 F9 Fiber Attachment mounted E39 F9 Pre wired Amplifier Units E3X DAC11 S E3X...

Page 14: ...rack mounting 12 95 A dia 12 95 A dia Fiber Attachment mounted E39 F9 Fiber Attachment mounted E39 F9 4 3 141 1 141 1 8 1 4 3 141 1 141 1 8 1 Amplifier Units with Connectors E3X DAC6 S E3X DAC8 S Cabl...

Page 15: ...uctor 1 conductor Standard length 2 m Conductor cross section 0 2 mm2 AWG24 Insulator diameter 1 1 mm Edge of amplifier Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Do...

Page 16: ...y standards codes or regulations which apply to the combination of the Product in the Buyer s application or use of the Product At Buyer s request Omron will provide applicable third party certificati...

Page 17: ...odes or regulations which apply to the combination of the Product in the Buyer s application or use of the Product At Buyer s request Omron will provide applicable third party certification documents...

Reviews: