Ratings and Specifications

Fiber Amplifier Units

N

ote: Refer to page 4 for 

*

1

 to 

*

6

.

Type

Standard models

Advanced models with simultaneous 

2-color determination 

Advanced models with 

4-color determination

Item

Model

E3X-DAC

@

-S

@

 (

@

: 11/41/6/8)

E3X-DAC

@

-S (

@

: 21/51)

E3X-DAC

@B

-S (

@

: 21/51)

Sensing distance

Depends on the Fiber Unit. Refer to page 5 to 7 for details.

Sensing object

Reflective models: Standard 11 color cards 

*

1, Through-beam models: Opaque or translucent object

Light source (wavelength)

W

hite LED (420 to 700 nm)

Sensing method

C Mode: RGB ratio determination (or I Mode: Light intensity determination for red, green, or blue; 
Black Mode: Determination of total light intensity for red, green, and blue) 

*

2

Number of registered 
colors

1


(simultaneous determination)


(2-color simultaneous 
determination 

×

 2 banks)

Power supply voltage

12 to 24 

V

DC 

±

10%, ripple (p-p) 10% max.

Power consumption

960 m

W

 max. (current consumption: 40 mA max. at power supply voltage of 24 

V

DC)

Control outputs

N

P

N

 or P

N

P open collector

Load power supply voltage: 26.4 

V

DC max.

Load current: 50 mA max. (residual voltage: 2 

V

 max.)

Number of control outputs

1

2

External input 

*

3 (page 4)

---

Remote control

Bank switching

Protection circuits

Reverse polarity for power supply connection, Output short-circuit, Reversed output polarity protection

Response
time

Super-high-speed mode 

*

4

High-speed mode
Standard mode
High-resolution mode

Operate or reset: 60

μ

s

Operate or reset: 300

μ

s

Operate or reset: 1 ms
Operate or reset: 4 ms

Operate or reset: 120

μ

s

Operate or reset: 600

μ

s

Operate or reset: 2 ms
Operate or reset: 

8

 ms

Sensitivity setting (color regis-
tration, allowable range)

Teaching (one-point teaching or teaching with/without workpiece) or manual adjustment

Functions

Operation mode

O

N

 for match (O

N

 for same color as registered color) or O

N

 for mismatch (O

N

 for different color from registered color)

Timer function

Timer type: OFF delay, O

N

 delay, or one-short, Timer time: 1 ms to 5 s (variable)

Control outputs

---

Output for each channel, A

N

D output, and OR output

Remote control

---

One-point teaching, teaching 
with/without workpiece, zero 
reset, and light emission OFF

Bank switching
(switching between banks A 
and B and banks C and D)

Display switch 

*

5

Seven patterns total: Match + Threshold,  Threshold, Analog bar display, Peak + Bottom, etc.

Initialization

Initial reset (factory defaults) or user reset (saved settings)

Initial reset (factory defaults)

Zero reset

Supported

N

ot supported

Indicators

Operation indicator (orange)/I 
mode display indicator (orange)

Operation indicator for each channel (orange) 

Digital display

7-segment displays (Main display: Red, Sub-display: Green)

Display direction

Switchable between normal and reversed.

Ambient illumination (Receiver 
side)

Incandescent lamp: 3,000 lux
Sunlight: 10,000 lux

Ambient temperature range 

*

6

Operating: 

25

°

C to 55

°

C, Storage: 

30

°

C to 70

°

C (with no icing or condensation)

Ambient humidity range

Operating and storage: 35% to 

8

5% (with no condensation)

Insulation resistance

20 M

Ω

 min. (at 500 

V

DC)

Dielectric strength

1,000 

V

AC at 50/60 Hz for 1 minute

Vibration resistance

Destruction: 10 to 50 Hz with a 1.5-mm double amplitude for 2 h each in X, Y and Z directions

Shock resistance

Destruction: 500 m/s

2

, for 3 times each in X, Y and Z directions

Degree of protection

IEC IP50 (with Protective Cover attached)

Connection method

Pre-wired (standard cable length: 
2 m) or reduced-wiring connector 
(Units connected: 16 max.)

Pre-wired (standard cable length: 2 m)

Weight (packed state)

Pre-wired model: Approx. 100 g, Amplifier unit connector model: Approx. 55 g

Materials

Case

Polybutylene terephthalate (PBT)

Cover

Polycarbonate (PC)

Accessories

Instruction manual

Downloaded from

Arrow.com.

Downloaded from

Arrow.com.

Downloaded from

Arrow.com.

Summary of Contents for E3X-DAC-S Series

Page 1: ...ee parameters RGB to enable stable detection even when the workpiece moves Not Affected by Move ment Intensity Detection Previous Type Color Detection Color Sensing Type Easy and Reliable Featuring a...

Page 2: ...X DAC41 S 2M Advanced models with simultaneous 2 color determination Standard models Simultaneous 2 color determination AND OR output Remote setting E3X DAC21 S 2M E3X DAC51 S 2M Advanced models with...

Page 3: ...for same color as registered color or ON for mismatch ON for different color from registered color Timer function Timer type OFF delay ON delay or one short Timer time 1 ms to 5 s variable Control out...

Page 4: ...ansistor NPN ON Shorted to 0 V sourcing current 1 mA max OFF Open or shorted to Vcc ON 1 5 V max sourcing current 1 mA max OFF Vcc 1 5 V to Vcc leakage current 0 1 mA max PNP ON Shorted to Vcc sinking...

Page 5: ...19 15 13 4 5 4 1 3 2 4 1 5 E32 D21 E32 D22B 8 8 6 7 5 8 2 1 1 8 1 3 1 1 0 7 E32 D25XB 14 10 9 3 3 2 1 1 7 1 1 Fluorine coating E32 D11U 42 32 26 11 8 5 6 5 3 5 Special beam models Long dis tance high...

Page 6: ...ating E32 T11U 190 140 120 60 40 28 24 20 Special beam models Long dis tance high power E32 T17L 4300 3200 2800 1400 900 600 500 460 E32 TC200 E39 F1 1100 850 700 360 220 160 140 120 E32 T11R E39 F1 1...

Page 7: ...00 E32 T61 S E39 F2 120 95 80 42 26 19 16 14 E32 T84S S 360 280 240 120 75 55 46 40 Chemical resistant E32 T11F 550 420 360 180 110 80 70 60 E32 T12F 850 650 550 280 180 120 100 95 E32 T14F 100 80 70...

Page 8: ...Red purple Black White Red Yellow red Yellow Yellow green Green Blue green Blue Blue purple Purple Red purple Black Number of colors differentiated combinations 0 20 40 60 80 100 120 140 0 Sensing di...

Page 9: ...24 VDC Display For the E3X DAC B S Match Mismatch ON OFF ON OFF Operate Reset Output transistor Between brown and black leads Operation indicator orange Load e g relay Between blue and black leads Ma...

Page 10: ...ding on application conditions such as the ambient temperature and the power supply voltage Use caution when operating or performing maintenance on the Sensor Fiber Amplifier Units Standard Models E3X...

Page 11: ...on the Connector and remove it Do not attempt to remove Connectors without separating them from other Amplifier Units first Adding and Removing Fiber Amplifier Units Adding Fiber Amplifier Units 1 Mo...

Page 12: ...plifier Units can be slid together and used in groups Do not however slide the Amplifier Units or attempt to remove any of the Amplifier Units during operation Others Protective Cover Always keep the...

Page 13: ...N End Plate sold separately PFP M Multiple connection diagram Two 2 4 dia DIN track mounting Fiber Attachment mounted E39 F9 Fiber Attachment mounted E39 F9 Pre wired Amplifier Units E3X DAC11 S E3X...

Page 14: ...rack mounting 12 95 A dia 12 95 A dia Fiber Attachment mounted E39 F9 Fiber Attachment mounted E39 F9 4 3 141 1 141 1 8 1 4 3 141 1 141 1 8 1 Amplifier Units with Connectors E3X DAC6 S E3X DAC8 S Cabl...

Page 15: ...uctor 1 conductor Standard length 2 m Conductor cross section 0 2 mm2 AWG24 Insulator diameter 1 1 mm Edge of amplifier Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Do...

Page 16: ...y standards codes or regulations which apply to the combination of the Product in the Buyer s application or use of the Product At Buyer s request Omron will provide applicable third party certificati...

Page 17: ...odes or regulations which apply to the combination of the Product in the Buyer s application or use of the Product At Buyer s request Omron will provide applicable third party certification documents...

Reviews: