background image

A-459

E3C-LDA Series

E3C-L

DA Series

Power tuning can be used to adjust the incident light level that is 
currently being received to the power tuning target value (default: 2,000). 
Before tuning ON the power, always secure the detection object and Head and be sure that the incident light level is stable.

The power tuning target value can be changed. Refer to Detailed Settings.

The incident light level may change when the detection method is changed.
If necessary, retune the power after changing the detection method.

Setting Method

Confirm that the MODE key setting is PTUN (power tuning) in advance. PTUN is the default setting. Refer to Detailed Settings.

Setting Errors

An error has occurred if one of the following displays appears after the progress bar is displayed.

Clearing Method

Over Error
The incident light level is too low for the power tuning target value.
The power can be increased up to approximately 1.5 times the incident light level without power tuning.

Bottom Error
The incident light level is too high for the power tuning target value.
The power can be decreased down to approximately 1/8th the incident light level without power tuning.

Timeout Error
An error occurred because the incident light level was not stable during power tuning. Make sure that the work-
piece and Head are secured and retune the power.

RUN

SET

Switch to RUN mode.

Tuning completed and previous display returns.

Main Display

Press the MODE key for at least 3 seconds.

Power tuning target value

PTUN

During power tuning

Progress bar

PTUN

A progress bar will appear on 

the sub-display one digit at a 

time. 

(Release the MODE key when 

the progress bar appears.)

Display alternates
 at a fixed interval.

PTUN

OVER

Flashes twice

PTUN

BOTM

Flashes twice

PTUN

TOUT

Flashes twice

Switch to RUN mode

PTUN

OFF

RUN

SET

Hold down the MODE key and press the DOWN key for at least 3 seconds.  

Note:

 Press the DOWN key right after pressing the MODE key.

The sub-display will flash twice and power tuning will be cleared.

+

Summary of Contents for E39-P31

Page 1: ...od Focus Model number Remarks Diffuse reflective Spot E3C LD11 Mounting a Beam Unit sold separately allows the use of line and area beams Line E3C LD21 This model number is for the set consisting of t...

Page 2: ...fective area 23 23 mm E39 R12 Standard Effective area 7 7 mm E39 R13 Transparent detection Effective area 23 23 mm E39 R14 Sheet cuttable Effective area 195 22 mm E39 RS4 Sheet cuttable Effective area...

Page 3: ...centage threshold incident light peak level no in cident light bottom level minimum incident light peak level maximum no incident light bottom level long bar display in cident level peak hold incident...

Page 4: ...Changes the setting in reverse MODE key Depends on the MODE key setting Executes power tuning default set ting Executes a zero reset Switches the function to be set on the display Mode Main display r...

Page 5: ...p to approximately 1 5 times the incident light level without power tuning Bottom Error The incident light level is too high for the power tuning target value The power can be decreased down to approx...

Page 6: ...eaching for a Reflective Sensor Head is performed without a workpiece i e for the background A value about 6 greater than the incident light level is set as the threshold value This method is ideal to...

Page 7: ...DOWN key for at least 3 seconds Threshold value RFCT Setting Errors RFCT OVER Flashes twice Teaching completed and previous display returns The threshold value that was set will flash twice Do one of...

Page 8: ...he following and then repeat the operation Adjust the Head to decrease the incident light level Execute power tuning Do one of the following and then repeat the operation Adjust the Head to increase t...

Page 9: ...ling edge are detected 250 s 500 s 500 s 1 ms 1 ms 2 ms 10 ms 20 ms 100 ms 200 ms Single edge This setting depends on the setting for the differential edge selection Switch to SET mode Double edge Sta...

Page 10: ...ntage of the threshold value and the threshold value The incidient light peak level and no incident light bottom level The min incidient light peak level and max no incident light bottom level The dis...

Page 11: ...and when the input turns OFF the average of these values is set as the threshold value Disabled if the detection function is set to DIFF differential operation A B A B Output for each channel 2OUT AR...

Page 12: ...cified count value The count is decremented from the specified count value each time an ob ject is detected and the output is tur ned ON when the count reaches 0 A B Write results to EEPROM ON OFF Do...

Page 13: ...pressing the MODE key The sub display will flash twice and key input will be disabled If a key is pressed while key operations are locked LOC will flash twice on the display to indicate that key oper...

Page 14: ...n be joined 1 Mount the Amplifier Units one at a time onto the DIN Track 2 Slide the Amplifier Units together and press the Amplifier Units together until they click into place Secure the Units with a...

Page 15: ...xternal input Blue E3C LDA21 and E3C LD7 NPN Models E3C LDA51 and E3C LD9 PNP Models Internal circuits Load 12 to 24 VDC Brown Black Orange Blue Output for chan Output for chan Output for chan Output...

Page 16: ...nterest of product improvement specifications are subject to change without notice ALL DIMENSIONS SHOWN ARE IN MILLIMETERS To convert millimeters into inches multiply by 0 03937 To convert grams into...

Reviews: