A-463
E3C-LDA Series
E3C-L
DA Series
Detailed Settings
The following functions can be set in SET mode. The default settings are shown in the transition boxes between functions.For Twin-
output Models, all settings except for the operation mode and timer settings are the same for both channels.
Note:
The values shown for thresholds, incident light levels, percentages, etc., are examples only. Actual displays may vary.
RUN
SET
Teaching
(Light level/Threshold display)
0. Operation Mode
Light-ON
LON
DON
Dark-ON
Single edge
Either the rising or falling
edge is detected.
Double edge
Both the rising and falling
edge are detected.
250
µ
s
500
µ
s
500
µ
s
1 ms
1 ms
2 ms
10 ms
20 ms
100 ms
200 ms
Single edge
This setting depends on the setting for
the differential edge selection.
Switch to SET mode.
Double edge
Standard mode
Response time: 1 ms
STND
HRES
High-resolution mode
Response time: 4 ms
DIFF
Not
SHS
Super-high-speed mode
Twin-output Models: 100
µ
s
Counter disabled for External-input Models: 80
µ
s
Counter enabled for External-input Models: 100
µ
s
1. Detection Method
Differential
Edge Selection
Differential
Response Time
(Twin-output Models only)
Set separately for each channel.
Note: Refer to
Basic Settings
for teaching methods.
Differential operation mode
Operation is according to the change
in the incident light level.
For Twin-output Models, the output for
channel 2 is always an alarm output for
A
B