A-465
E3C-LDA Series
E3C-L
DA Series
The item that is controlled by the input from an external
device can be selected.
Through-beam, no-workpiece teaching
THRU
RFCT
Reflective, no-workpiece teaching
2PNT
With/Without workpiece teaching
Effective Pulse Widths
AUTO
PTUN
Power tuning
0RST
Zero reset
0.1 to 2 s
Executing: 0.1 to 2 s
Clearing: 3 s or longer
Effective ON pulse
width: 0.1 s min.
Selection
Pulse width
LOFF
Light OFF (The light will remain OFF as
long as the input is ON.)
CRST
Counter reset
Resets the current counter value.
(External-input Models Only)
7. External Input
,
,
,
Automatic teaching
The maximum and minimum light le-
vels are sampled while the input is ON
and, when the input turns OFF, the
average of these values is set as the
threshold value.
Disabled if the detection function is set
to "DIFF" (differential operation).
A
B
A
B
Output for each channel.
2OUT
AREA
Output if level is between the two
thresholds.
SELF
The function of the output for channel 2 can be selected.
This setting is not value if DIFF (differential operation)
is set for the detection method. (The output for channel
2 is always an alarm output for differential operation.)
7. Twin Outputs
(Twin-output Models Only)
The output for channel 1 functions according to the
detection mode selection.
Self-diagnosis output
Output when the incident light le-
vel
is not stable, i.e., when the light le-
vel is ±10% of the threshold value
Normal display
D123
321D
Reversed display
6. Display
Orientation
Maximum power
FULL
Setting range: 100 to 3,900
5. Power Tuning
Target Value