background image

Terms and Conditions Agreement

Read and understand this catalog.

Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you 
have any questions or comments. 

Warranties.

(a) Exclusive Warranty. Omron’s exclusive warranty is that the Products will be free from defects in materials and workmanship 

for a period of twelve months from the date of sale by Omron (or such other period expressed in writing 
by Omron). Omron disclaims all other warranties, express or implied.

(b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT 

NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE 
PRODUCTS. BUYER ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE PRODUCTS WILL 
SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE.

Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the 
Products or otherwise of any intellectual property right. (c) Buyer Remedy. Omron’s sole obligation hereunder shall be, at Omron’s 
election, to (i) replace (in the form originally shipped with Buyer responsible for labor charges for removal or replacement thereof) 
the non-complying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amount equal to the purchase 
price of the non-complying Product; provided that in no event shall Omron be responsible for warranty, repair, indemnity or any 
other claims or expenses regarding the Products unless Omron’s analysis confirms that the Products were properly handled, 
stored, installed and maintained and not subject to contamination, abuse, misuse or inappropriate modification. Return of any 
Products by Buyer must be approved in writing by Omron before shipment. Omron Companies shall not be liable for the suitability 
or unsuitability or the results from the use of Products in combination with any electrical or electronic components, circuits, system 
assemblies or any other materials or substances or environments. Any advice, recommendations or information given orally or in 
writing, are not to be construed as an amendment or addition to the above warranty.

See http://www.omron.com/global/ or contact your Omron representative for published information.

Limitation on Liability; Etc.

OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES, 
LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, 
WHETHER SUCH CLAIM IS BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY.

Further, in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted.

Suitability of Use.

Omron Companies shall not be responsible for conformity with any standards, codes or regulations which apply to the 
combination of the Product in the Buyer’s application or use of the Product. At Buyer’s request, Omron will provide applicable 
third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself 
is not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine, 
system, or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product 
with respect to Buyer’s application, product or system. Buyer shall take application responsibility in all cases. 

NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE 
QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, 
AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE 
OVERALL EQUIPMENT OR SYSTEM.

Programmable Products.

Omron Companies shall not be responsible for the user’s programming of a programmable Product, or any consequence 
thereof.

Performance Data.

Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining 
suitability and does not constitute a warranty. It may represent the result of Omron’s test conditions, and the user must correlate 
it to actual application requirements. Actual performance is subject to the Omron’s Warranty and Limitations of Liability.

Change in Specifications.

Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our 
practice to change part numbers when published ratings or features are changed, or when significant construction changes are 
made. However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers 
may be assigned to fix or establish key specifications for your application. Please consult with your Omron’s representative at 
any time to confirm actual specifications of purchased Product.

Errors and Omissions.

Information presented by Omron Companies has been checked and is believed to be accurate; however, no responsibility is 
assumed for clerical, typographical or proofreading errors or omissions.

Summary of Contents for D41L

Page 1: ...ances Actuator tolerance in longitudinal direction 3 5 mm lateral direction 2 0 mm Easy latching force adjustment The latching force can be increased from 25 N to 50 N simply by turning the star handl...

Page 2: ...ding 2 High Individual coding No limitation 3 OSSD configuration Y Guard monitoring AND lock monitoring Z Only guard monitoring 4 Diagnosis output D With diagnosis output 5 Lock release logic A Power...

Page 3: ...ing Emergency exit D41L 2YDAE N2 Power to lock Solenoid lock High Individual coding Only guard monitoring D41L 1ZDG N2 High Individual coding No limitation Only guard monitoring D41L 2ZDG N2 High Indi...

Page 4: ...Standards EN ISO 13849 1 PL e Category 4 EN 60947 5 3 IEC 61508 EN 300 330 EN ISO 14119 UL Certification UL508 CAN CSA C22 2 No 14 Regions where D41L can be used The product can be used in Japan the...

Page 5: ...al short circuit current 100 A External device fuse rating 2 A T Safety input Switching thresholds 3 V to 5 V low 15 V to 30 V high Current consumption per input 5 mA 24 V max Accepted test pulse dura...

Page 6: ...ting speed 0 5 m s max Mechanical durability 1 000 000 operations min Mechanical durability when used as door stop 50 000 operations min Material Fiberglass reinforced thermoplastic self digestion Enc...

Page 7: ...afety door switches are involved in the same safety function the PFH values of the individual components must be added UL This device is intended to be powered by a Listed Limited Voltage Limited Curr...

Page 8: ...ed 3 Star handle adjustable latching force 25 N or 50 N 4 Mounting hole for M6 screws 5 Connector plug M12 8 pole 6 Manual release 7 LED display 8 Triangular both sides for installation of the emergen...

Page 9: ...When connecting multiple safety door switches in series apply 24 VDC to safety inputs X1 and X2 on the Nth unit as shown in the figure below Connect safety outputs Y1 and Y2 to safety inputs X1 and X2...

Page 10: ...al User s Manual Refer to the Dual Channel Evaluation in No Z400 Example Set discrepancy time to 0 disabled or 100 ms or more G9SP series Safety Controller User s Manual Refer to the Dual Channel Eval...

Page 11: ...op The safety outputs switch off and the guard system can be opened The blocked position is cancelled by turning the lever in the opposite direction In the unlocked position the guard system is secure...

Page 12: ...ctivated code is definitively saved For ordering suffix D41L 1 the thus executed allocation of safety door switch and actuator is irreversible When the above procedure is attempted with a D41L 1 which...

Page 13: ...yed shutdown of the safety outputs Refer to Troubleshooting on page 17 Safety outputs are disabled if the error warning is active for 30 minutes The signal combination auxiliary output disabled and sa...

Page 14: ...s Unit mm Sensors D41L D N2 87 4 78 102 6 43 34 dia 9 2 25 95 3 13 3 6 5 d i a 6 3 d i a 120 3 17 5 34 4 D41L D E N2 17 5 55 34 4 87 4 78 102 6 43 34 dia 9 2 25 95 3 13 3 6 5 d i a 120 3 6 3 d i a 128...

Page 15: ...Actuator Sold separately Accessory Sold separately D41L A1 55 16 4 127 6 7 dia 35 18 5 37 4 8 6 46 23 4 5 dia Mounting plate Mounting Set Mounting plate D41L MP 40 24 R2 5 101 R 1 5 R 8 18 5 78 8 6 8...

Page 16: ...ce inherent to this kind of system and any reduction of the switching distances please observe the following guidelines The presence of metal chips in the vicinity of the safety door switch is liable...

Page 17: ...uts Y1 Y2 Auxiliary output OUT Power to unlock Power to lock Green Red Yellow D41L Y D41L Z Guard open 24 V 0 V 0 V 24 V On Off Off 0 V 0 V 0 V Door closed not locked 24 V 0 V On Off Flashes 0 V 24 V...

Page 18: ...to do so may result in serious injury or death Make sure that the DC power supply meets the following items Failure to do so may result in serious injury or death Satisfies the requirements of PELV p...

Page 19: ...protection under continuous water exposure environment 19 Do not tamper the product with a replacement actuator Store replacement actuators in a safe place where they cannot be easily reached 20 Buil...

Page 20: ...uld not be possible to lock the guard door from inside Maintenance Maintenance frequency SIL3 PLe at least once a month SIL2 PLd at least once a year Daily inspection For each guard door check that th...

Page 21: ...CONNECTED WITH THE PRODUCTS WHETHER SUCH CLAIM IS BASED IN CONTRACT WARRANTY NEGLIGENCE OR STRICT LIABILITY Further in no event shall liability of Omron Companies exceed the individual price of the Pr...

Page 22: ...D41D A3 Installation example sliding door narrow space Compact size for acrylic glass doors For the most recent information on models that have been certified for safety standards refer to your OMRON...

Reviews: