D41L
11
Release
Manual Release
For the machine set-up, the safety door switch can be unlocked in a de-energized condition.
The safety door switch is unlocked by turning the manual release in the position (unlock).
The normal locking function is only restored after the manual release has been returned to its original position (lock).
After being put into operation, the manual release must be sealed by means of the seal, which is included in delivery.
Emergency exit (D41L-
@@
D
@
E-N2)
To activate the emergency exit, turn the red lever in the direction of the arrow to the end stop. The safety outputs switch off and the guard system
can be opened. The blocked position is cancelled by turning the lever in the opposite direction. In the unlocked position, the guard system is
secured against unintentional locking.
With variants that have emergency-exit, the red lever is included with delivery.
The lever should be fastened to the position intended with the supplied screws before first being used.
The lever should be installed on the unlocking triangle in such a way that the arrow on the triangle and the lever pivot are congruent. The installation
of the lever is possible on both sides.
The opposite is to be sealed with the seal included with delivery.
Fitting and actuation only from within the hazardous area.
POWER
STATUS
FAULT
Manual release