Online
to Transfer
Online
to Transfer
Monitoring
Monitoring
Force On
Force Off
Force On
Force Off
Program
Check
Program
Check
Online
Edit
Online
Edit
14. Changing Set Value of Timer
The set value of a timer is changed while CPU is running (in the Monitor mode only).
Move the cursor to the
set value of a timer.
Enter the new set value #100.
Click [OK] to complete.
15. Changing Present Value of Timer
Move the cursor to the
present value of a
timer.
Enter a new present value 5000.
Click [Set] to complete.
The present value of a timer is changed while CPU is running (in the Monitor mode only).
Subtraction starts from
the new value 5000.
ENT
Or double-click.
ENT
Or double-click.
Summary of Contents for CX-Programmer
Page 1: ......
Page 6: ......
Page 7: ......
Page 13: ...MEMO...
Page 21: ...5 Program Creation Coding of a simple program is explained here...
Page 39: ......
Page 60: ......