NoClocks
Register name
Sys.NoClocks
Description
Cannot detect a phase clock or a servo clock.
Range
0 to 1
Details
0: No error
1: Cannot detect a phase clock or a servo clock.
Detection timing
When power is turned ON or the Controller is reset.
Recovery
Cycle the power supply, or issue reset command ($$$)
Effects
Cannot enable the motor.
Cause and cor-
rection
Cause (Assumed cause)
Correction
Prevention
The clock-related register is
overwritten by the user pro-
gram.
If the error no longer occurs
after the re-initialization
command ($$$***) is exe-
cuted, review the user pro-
gram.
None
The Motion Controller
failed.
If the error still persists
even after the above cor-
rective actions have been
taken, replace the Motion
Controller.
None
Precautions/
Remarks
None
Default
Register name
Sys.Default
Description
Initialized to the factory default setting.
Range
0 to 1
Details
0: No error
1: Cases below
•
In the factory default state, or initialized to the factory default state by a re-initializa-
tion command ($$$***).
•
Configuration changed after save command was issued.
Detection timing
When power is turned ON or the Controller is reset.
Recovery
Cycle the power supply, or issue reset command ($$$)
Effects
Operation continues
Cause and cor-
rection
Cause (Assumed cause)
Correction
Prevention
Re-initialization command
($$$***) was issued.
None
None
ConfigLoadErr
occurred.
Check the corrective action
for each error.
None
Precautions/
Remarks
None
5 Error Processing
5-10
CK3E-series Programmable Multi-Axis Controller User’s Manual Hardware (I610)
Summary of Contents for CK3E Series
Page 6: ...Manual Structure 4 CK3E series Programmable Multi Axis Controller User s Manual Hardware I610 ...
Page 110: ...Appendices A 12 CK3E series Programmable Multi Axis Controller User s Manual Hardware I610 ...
Page 111: ...I Index I 1 CK3E series Programmable Multi Axis Controller User s Manual Hardware I610 I ...
Page 113: ......