06
Serial Number
Serial number Read
UDINT
Set value
07
Product Name
Product name Read
SHORT_STRING Set value
*1.
Product code
Model
Product code (hex)
CK3E-1210 0BE5
CK3E-1310 0BE6
CK3E-1410 0BE7
*2.
Status
Status
Value (hex)
The I/O connection is not established
0000
The I/O connection is established in RunMode 0060
The I/O connection is established in IdleMode
0070
A-3-2
Assembly Object (Class ID: 04 Hex)
The Assembly object is intended to join the I/O data of the CK3E.
Service Code
Service code
(hex)
Parameter name
Description
Supported services
Classes
Instances
0E
Get_Attribute_Single Reads the value of the specified attrib-
ute.
Supported
Supported
10
Set_Attribute_Single Writes the value of the specified attrib-
ute.
Not supported Supported
Class ID and Instance ID
The class ID and instance ID are as shown below.
ID type
Value (hex)
Class ID
04
Instance ID ED: Listen Only Heartbeat Assembly
EE: Input Only Heartbeat Assembly
300, 304, 308 to 37C (in 4 increments): Output Assembly
301, 305, 309 to 37D (in 4 increments): Input Assembly
Attribute ID
The attribute IDs for instances are as shown below.
Appendices
A-6
CK3E-series Programmable Multi-Axis Controller User’s Manual Hardware (I610)