CX-ConfiguratorFDT Main Window
Section 4-2
40
After exporting the information, the default browser is launched, showing the
result of the export process. The HTML file contains links to open the
information pages for the individual DTMs. The amount of the information
displayed depends on the individual DTMs. The displayed information can
range from only the device type and version information to up to all possible
settings and selections made for the device.
Exporting DTM Information
to HTML
To export single DTM information to HTML execute the following steps:
1,2,3...
1 Select the DTM in the Network view.
2 Right click the DTM to bring up the context menu.
3 Select the Export to HTML option from the context menu.
A window will pop up displaying the progress of the export process. When
finished, CX-ConfiguratorFDT will launch the default browser to display the
result. In this case, however, no links will be available to other DTMs in the
network.
4-2-4
Error Logging and FDT Monitoring
CX-ConfiguratorFDT provides two logging windows at the bottom of the
application window. Both windows are used for displaying events.
Error Log view
The Error Log view displays error messages reported by the DTMs and by the
CX-ConfiguratorFDT FDT container application. All messages include the
Time and Date of occurrence as well as the DTM Name, as shown in the
Network view.
Purpose of the Error log
The purpose of the Error Log view is error reporting and troubleshooting. The
contents of the window can be copied to the clipboard, for pasting to another
application or into an E-mail. The errors and the sequence in which they occur
may hold additional clues in case of problems.
Error Log Format
The format used in the Error Log view is:
Time:
<Time>
Date:
<Date>
-
<DTM name> <message>
The message displayed, originates from the DTM in which the error occurred.
The figure below shows an example of an error message sequence. This
example sequence is generated after attempting to change a slave address to
that of another slave already assigned to the same Master Unit
Figure 4.4: Error log
Right-clicking in the Error Log view displays a context menu providing the
options listed below.
/i
Summary of Contents for CJ1W-CRM21
Page 1: ...CJ1W PNT21 PROFINET IO Controller Unit OPERATION MANUAL Cat No W12E EN 02 ...
Page 2: ......
Page 7: ...vii ...
Page 16: ......
Page 26: ...Basic operating procedure Section 2 4 10 ...
Page 46: ...Installation of Configuration Software Section 3 5 30 ...
Page 76: ...Generic IO Device DTM Section 4 4 60 ...
Page 156: ...140 ...
Page 164: ...146 ...
Page 168: ...150 ...
Page 170: ...Section 152 ...