![Omron CJ1W-CRM21 Operation Manual Download Page 101](http://html1.mh-extra.com/html/omron/cj1w-crm21/cj1w-crm21_operation-manual_742074101.webp)
Setting up a Network
Section 7-2
85
1,2,3...
1 Open the Device Catalogue: Either select the View - Device Catalogue
menu option, or press the Device Catalogue button in the Tool Bar. The
opened Device Catalogue is shown below
Figure 7.2: Device catalogue
2 Check the list of available DTMs, and verify that all the devices that need to
be added to the Network - both IO Controllers and IO Devices - are among
the DTMs in the list.
3 If one or more of the DTMs is missing, these DTMs must first be installed
and the Device Catalogue updated.
Installing New GSDML
Files
GSDML files can be installed from within the Device Catalogue main window.
To do so, follow the procedure below.
DTM categories
Device name
Version number
File date
Vendor name
Update Device Catalogue
Install a new GSD or GSDML file
Add selected device to the network
Note
1 Non-GSDML file based DTMs are usually provided with their own
setup program. Installation of these DTMs must be performed out-
side CX-ConfiguratorFDT, e.g. from
Windows Explorer
.
2 In case of DTM installations outside CX-ConfiguratorFDT, always ini-
tiate an update of the Device Catalogue, before assembling a net-
work. Without this update the newly installed DTM will not appear in
the list of devices. To
Update
the Device Catalogue, press the
Update button in the Device Catalogue main window.
3 An Update must also be performed when an already existing DTM is
upgraded. Without the update, the old version number will still be
shown in the list. Failure to update the Device Catalogue in this case
may also result in undesired behaviour, when adding these DTMs to
the Network.
Summary of Contents for CJ1W-CRM21
Page 1: ...CJ1W PNT21 PROFINET IO Controller Unit OPERATION MANUAL Cat No W12E EN 02 ...
Page 2: ......
Page 7: ...vii ...
Page 16: ......
Page 26: ...Basic operating procedure Section 2 4 10 ...
Page 46: ...Installation of Configuration Software Section 3 5 30 ...
Page 76: ...Generic IO Device DTM Section 4 4 60 ...
Page 156: ...140 ...
Page 164: ...146 ...
Page 168: ...150 ...
Page 170: ...Section 152 ...