14
AC servo systems
Single-phase, 2
3
0 VAC(for analog/pulse servo drives)
*1 For servo drives from 750 W, B2 and B3 are short-circuited. If the internal regenerative resistor is insufficient, remove the wire between B2 and B3 and connect an
external regenerative resistor between B1 and B2.
*2 For use only with an absolute encoder. If a backup battery is connected to CN1 I/O connector, an encoder cable with a battery is not required.
*3 Only available in Position control mode.
*4 The input function depends on control mode used (Position, speed or torque control).
*5 Wiring diagram example using the G9SX safety unit. If a safety unit is not used, keep the factory safety bypass connector installed in the CN8.
Note:
The input function of pins 8,9 and 26 to 33, and output function of pins 10, 11, 34, 35, 38 and 39, can be changed via parameter settings.
S
14
A2
S
24
S3
4
S
44
S
54 L1
X1 X2
T11
A1
T12 T21 T22 T
3
1 T
3
2 T
33
Y1
T41 T42
G9
S
X
sa
fety
u
nit
*
5
Acc
u
r
a
x G5
An
a
log/P
u
l
s
e
S
ervo drive
Optic
a
l encoder
S
ervo motor
B
3
B2
U
V
W
B1
L1
L
3
L1C
L2C
Noi
s
e filter
S
ingle-Ph
as
e
200 to 2
3
0 VAC
Cont
a
ctor
L1
L2
L
3
N
Therm
a
l
s
witch
CN1
*
1
3
k
Ω
110
Ω
4
3
k
Ω
3
k
Ω
220
Ω
5
2
6
S
ervo ON
44
45
+CW
-CW
+CCW
-CCW
+CWLD
-CWLD
Rever
s
e p
u
l
s
e
Forw
a
rd p
u
l
s
e
BKIR
Br
a
ke rele
as
e
s
ign
a
l o
u
tp
u
t
Al
a
rm o
u
tp
u
t
BKIRCOM
11
10
READY
READYCOM
ALMCOM
3
5
3
4
/ALM
3
7
3
6
INPCOM
INP
3
9
38
3
2
TV
S
EL
3
1
RE
S
ET
3
0
ECR
S
T
2
8
GE
S
EL1
27
G
S
EL
26
DF
S
EL1
29
RUN
7
+24 VIN
Control mode
s
witching
Al
a
rm re
s
et
Devi
a
tion co
u
nter re
s
et
Electronic ge
a
r
s
witching
G
a
in
s
witching
Vi
b
r
a
tion filter
s
witching
12 to 24 VDC
Extern
a
l power
su
pply 12 to 24 VDC
M
a
xim
u
m
s
ervice volt
a
ge:
3
0 VDC
M
a
xim
u
m
o
u
tp
u
t c
u
rrent: 50 mADC
Rever
s
e p
u
l
s
e
46
47
110
Ω
4
3
k
Ω
33
IPG
P
u
l
s
e prohi
b
ition
500 kpp
s
m
a
x.
2 Mpp
s
m
a
x.
8
NOT
Rever
s
e r
u
n
prohi
b
ited
9
POT
Forw
a
rd r
u
n
prohi
b
ited
ZCOM
Z Ph
as
e-Z o
u
tp
u
t
(open-collector o
u
tp
u
t)
1
8
10 k
Ω
3
.
83
k
Ω
PCL/TREF2
NCL
AGND1
Rever
s
e tor
qu
e limit
3
.
83
k
Ω
16
17
10 k
Ω
19
25
Fr
a
me gro
u
nd
FG
50
4.7 k
Ω
4.7 k
Ω
4.7 k
Ω
4.7 k
Ω
4
3
k
Ω
3
k
Ω
+CCWLD
-CCWLD
Forw
a
rd p
u
l
s
e
+A
Encoder ph
as
e-A o
u
tp
u
t
Encoder ph
as
e-B o
u
tp
u
t
Encoder ph
as
e-Z o
u
tp
u
t
21
-A
22
+B
49
-B
4
8
+Z
2
3
-Z
24
Line-driver o
u
tp
u
t corre
s
ponding
with the EIA R
S
-422A comm
u
nic
a
tion
s
method (lo
a
d re
s
i
s
t
a
nce 120 W min.)
220
Ω
3
1
4
4
3
k
Ω
3
k
Ω
4.7 k
Ω
4.7 k
Ω
4.7 k
Ω
4.7 k
Ω
4.7 k
Ω
4.7 k
Ω
+24 VCW
2.2 k
Ω
+24 VCCW
2.2 k
Ω
20
100
Ω
4.7 k
Ω
1 µF
S
EN
S
ENGND
1
3
S
en
s
or ON
BAT
BATGND
B
a
ck
u
p
ba
ttery
*
2
(
3
.6 V)
42
4
3
Po
s
ition reference
*3
REF/TREF1/VLIM
AGND
3
.
83
k
Ω
14
15
20 k
Ω
Forw
a
rd tor
qu
e limit/Tor
qu
e comm
a
nd
*
4
(±12 V/r
a
ted
s
peed or tor
qu
e)
Rever
s
e tor
qu
e limit
*
4
(±12 V/r
a
ted
s
peed or tor
qu
e)
S
peed/Tor
qu
e comm
a
nd or
S
peed limit
*
4
(±10 V/r
a
ted
s
peed or tor
qu
e)
S
hell
S
F1+
S
F1-
4
3
1kW
4kW
8
EDM+
EDM-
FG
7
10
S
F2+
S
F2-
6
5
1kW
4kW
CN
8
+24 V
S
1
+24 V +24 V
+24 V +24 V
CNB
CNA
CN2
EDM o
u
tp
u
t: monitor
s
ign
a
l to detect
a
sa
fety
f
u
nction f
a
il
u
re
(M
a
xim
u
m
s
ervice volt
a
ge:
3
0 VDC or le
ss
M
a
xim
u
m o
u
tp
u
t c
u
rrent: 50 mADC)
S
ervo re
a
dy o
u
tp
u
t
Po
s
itioning completed o
u
tp
u
t