Accurax G5 servo drive
7
I/O signals (CN1) - Input signals (for analog/pulse servo drives)
Pin No.
Control mode Signal name
Function
1
Position/
Full close loop
+24 VCW
Reference pulse input for line driver and open collector according to parameter setting.
Input mode:
Sign + pulse string
Reverse/forward pulse (CCW/CW pulse)
Two-phase pulse (90° phase differential)
3
+CW
4
-CW
2
+24 VCW
5
+CCW
6
-CCW
44
+CWLD
Reference pulse input for line driver only.
Input mode:
Reverse/forward pulse (CCW/CW pulse)
45
-CWLD
46
+CCWLD
47
-CCWLD
14
Speed
REF
Speed reference input: ±10 V/rated motor speed (input gain can be modified using a parameter).
Torque
TREF1
Torque reference input: ±10 V/rated motor torque (input gain can be modified using a parameter).
VLIM
Speed limit input: ±10 V/rated motor speed (input gain can be modified using a parameter).
15
-
AGND1
Analog signal ground
16
Torque
TREF2
Torque reference input: ±10 V/rated motor torque (input gain can be modified using a parameter).
Position/Speed
Full close loop
PCL
Forward torque limit input: ±10 V/rated motor torque (input gain can be modified using a parameter).
18
NCL
Reverse torque limit input: ±10 V/rated motor torque (input gain can be modified using a parameter).
17
-
AGND1
Analog signal ground
7
Common
+24 VIN
Control power supply input for sequence signals: users must provide the +24 V power supply (12 to 24 V).
29
RUN
Servo ON: this turn ON the servo.
26
Position/Full
close loop
DFSEL1
Vibration filter switching 1
Enables vibration filter according parameter setting.
27
Common
GSEL
Gain switching
Enables gain value according parameter setting.
28
Position/Full
close loop
GESEL1
Electronic gear switching 1
Switches the numerator fro electronic gear ratio.
Speed
VSEL3
Internal speed selection 3
Input to select the desired speed setting during internally speed operation.
The speed selecton is combining this input with VSEL1 and VSEL2 inputs.
30
Position/Full
close loop
ECRST
Error counter reset input.
Resets the position error counter.
Speed
VSEL2
Internal speed selection 2
Input to select the desired speed setting during internally speed operation.
The speed selecton is combining this input with VSEL1 and VSEL3 inputs.
31
Common
RESET
Alarm reset input.
Release the alarm status. The error counter is reset when the alarm is reset.
32
Position/
Speed/Torque
TVSEL
Control mode switching
33
Position
IPG
Pulse prohibition input. Digital input to inhibit the position reference pulse.
Speed
VSEL1
Internal speed selection 1
Input to select the desired speed setting during internally speed operation.
The speed selecton is combining this input with VSEL2 and VSEL3 inputs.
8
Coomon
NOT
Reverse run prohibited
Overtravel prohibited: stops servomotor when movable part travels beyond the
allowable range of motion.
9
POT
Forward run prohibited
20
Position/
Speed/Torque
SEN
Sensor ON input. Initial data request signal when using an absolute encoder.
13
SENGND
Sensor ON signal ground.
42
Common
BAT (+)
Backup battery connection terminals when the absolute encoder power is interrupted. Do not connect when a absolute
encoder battery cable for backup is used.
43
BATGND (-)
50
FG
Frame ground
-
-
TLSEL
Torque limit switch
The function of input signals allocated to pins 8,9 and 26 to 33 can be changed with
these options by parameters settings
DFSEL2
Vibration filter switching 2
GESEL2
Electronic gear switching 2
VZERO
Zero speed
VSIGN
Speed command signal
TSIGN
Torque command signal
E-STOP
Emergency stop
JSEL
Inertia ratio switching
12
-
Terminals not used. Do not connect.
40
-
41
-
Po