background image

H3RN

H3RN

6

Nomenclature

Run/Power Indicator (Green)

(Lit: Power ON)

Output Indicator (Orange)

(Lit: Output ON)

Main Dial

Set the desired time according to time
range selectable by DIP switch.

Operation

Timing Chart

Operating mode

Timing chart

H3RN-1/-11

H3RN-2/-21

ON-delay

Power

Output

Time limit contact
NC (4-2)

Run/Power
indicator (PW)

Output indicator
(OUT)

Power (1-5)

Time limit contact
NO (4-3)

Power (1-8)

Time limit contact
NO (4-3, 5-6)

Run/Power
indicator (PW)

Output indicator
(OUT)

Interval

Power

Output

Time limit contact
NC (4-2)

Run/Power
indicator (PW)

Output indicator
(OUT)

Power (1-5)

Time limit contact
NO (4-3)

Power (1-8)

Time limit contact
NO (4-3, 5-6)

Run/Power
indicator (PW)

Output indicator
(OUT)

Flicker OFF-start

Power

Output

Time limit contact
NC (4-2)

Run/Power
indicator (PW)

Output indicator
(OUT)

Power (1-5)

Time limit contact
NO (4-3)

Power (1-8)

Time limit contact
NO (4-3, 5-6)

Run/Power
indicator (PW)

Output indicator
(OUT)

Flicker ON-start

Power

Output

Time limit contact
NC (4-2)

Run/Power
indicator (PW)

Output indicator
(OUT)

Power (1-5)

Time limit contact
NO (4-3)

Power (1-8)

Time limit contact
NO (4-3, 5-6)

Run/Power
indicator (PW)

Output indicator
(OUT)

Note:

t:

Set time

Rt: Reset time

Summary of Contents for 70179796

Page 1: ...e model 0 1 s to 10 min Long time range model 0 1 min to 10 h 24 VAC 12 24 VDC SPDT H3RN 1 H3RN 11 12 24 VDC DPST NO H3RN 2 H3RN 21 Note Specify both the model number and supply voltage when ordering Example H3RN 1 24 VAC Supply voltage Model Number Legend H3RN jj 1 2 1 Output 1 SPDT 2 DPST NO 2 Time Range None Short time range 0 1 s to 10 min 1 Long time range 0 1 min to 10 hrs Accessories Order ...

Page 2: ...ance 100 M min at 500 VDC Dielectric strength 2 000 VAC 50 60 Hz for 1 min between operating circuit and control output or contacts of different poles 1 000 VAC 50 60 Hz for 1 min between non continuous contacts Vibration resistance Destruction 10 to 55 Hz 0 75 mm single amplitude Malfunction 10 to 55 Hz 0 5 mm single amplitude Shock resistance Destruction 300 m s2 approx 30G Malfunction 100 m s2 ...

Page 3: ... Power Output Time limit contact NC 4 2 Run Power indicator PW Output indicator OUT Power 1 5 Time limit contact NO 4 3 Power 1 8 Time limit contact NO 4 3 5 6 Run Power indicator PW Output indicator OUT Flicker OFF start Power Output Time limit contact NC 4 2 Run Power indicator PW Output indicator OUT Power 1 5 Time limit contact NO 4 3 Power 1 8 Time limit contact NO 4 3 5 6 Run Power indicator...

Page 4: ...1 s 0 1 to 1 s Yes 10 s 1 to 10 s No 1 min 0 1 to 1 min No 10 min 1 to 10 min No H3RN 11 H3RN 21 1 min 0 1 to 1 min Yes 10 min 1 to 10 min No 1 h 0 1 to 1 h No 10 h 1 to 10 h No Note The left two DIP switch pins are used to select the time ranges Operating Modes Operating mode Setting Factory set ON delay Yes Interval No Flicker OFF start No Flicker ON start No Note The right two DIP switch pins a...

Page 5: ...h 05 for SPDT or 08 for DPST NO P2RF j E P2R j7P Note 1 The value shown indicates the dimension for the P2RF 05 E with the PFP jN Mounting Rail The value is 71 5 mm when using the PFP Nj2 2 The value shown in parentheses indicates the di mension for the P2RF 08 E with the PFP jN Mounting Rail The value is 75 5 mm when using the PFP Nj2 P2RF j E Socket H3RN Series H3RN Series P2R j7P Socket 80 9 se...

Page 6: ...e as shown in the following timing charts H3RN 2 21 Note t Set time Rt Reset time Timer circuit External input Power 3 8 External short circuit 1 4 External input 1 3 Time limit contact NO 6 5 Run Power indicator PW Output indicator OUT 50 ms min Caution Be careful when connecting wires Mode Terminals Pulse operation Power supply between 3 and 8 Short circuit between 4 and 1 Input signal between b...

Page 7: ...y cause short cir cuiting at three points otherwise short circuiting of the power sup ply may occur because the SPDT contact of H3RN 1 11 is com posed of an SPST NC contact Power supply for load Short circuit current 3 4 2 1 5 Donot set totheminimum settingintheflickermodes otherwisethe contact may be damaged Donot usetheH3RNinplaces wherethereis excessive dust corro sive gas or direct sunlight Ma...

Page 8: ...H3RN H3RN 11 ...

Page 9: ...pan Phone 06 949 6012 Fax 06 949 6021 ALL DIMENSIONS SHOWN ARE IN MILLIMETERS To convert millimeters into inches multiply by 0 03937 To convert grams into ounces multiply by 0 03527 Cat No L090 E1 1B In the interest of product improvement specifications are subject to change without notice Printed in Japan 0996 2M 0296 a ...

Reviews: