H3RN
H3RN
5
Specifications
Ratings
Item
H3RN-1/-2
H3RN-11/-21
Time ranges
0.1 s to 10 min (1 s, 10 s, 1 min, or 10 min
max. selectable)
0.1 min to 10 h (1 min, 10 min, 1 h, or 10 hrs
max. selectable)
Rated supply voltage
24 VAC; 12, 24 VDC
Pin type
Plug-in
Operating mode
ON-delay, interval, flicker OFF-start, or flicker-ON start selectable by DIP switch
Operating voltage range
85% to 110% of rated supply voltage (12 VDC: 90% to 110% of rated supply voltage)
(see note)
Power consumption
24 VAC:
Relay ON:
approx. 0.8 VA (at 24 VAC, 60 Hz)
Relay OFF:
0.5 VA (at 24 VAC, 60 Hz)
12 VDC:
Relay ON:
approx. 0.4 W (at 12 VDC)
Relay OFF:
0.1 W (at 12 VDC)
24 VDC:
Relay ON:
approx. 0.5 W (at 24 VDC)
Relay OFF:
0.2 W (at 24 VDC)
Control outputs
3 A at 250 VAC, resistive load (cos
!
= 1) (G6B-2
j
14P-FD-US used)
The minimum applicable load is 10 mA at 5 VDC (P reference value).
Note:
When using the H3RN in any place where the ambient temperature is more than 50
"
C, supply 90% to 110% of the rated voltages
(12 VDC: 95% to 110% of the rated voltage).
Characteristics
Item
H3RN-1/-2
H3RN-11/-21
Accuracy of operating time
#
1% FS max. (1 s range:
#
1%
#
10 ms max.)
Setting error
#
15%
#
50 ms FS max.
Reset time
Min. power-opening time: 12, 24 VDC: 0.1 s max. (including halfway reset)
24 VAC:
0.5 s max. (including halfway reset)
Influence of voltage
#
2% FS max.
Influence of temperature
#
2% FS max.
Insulation resistance
100 M
$
min. (at 500 VDC)
Dielectric strength
2,000 VAC, 50/60 Hz for 1 min (between operating circuit and control output, or contacts of
different poles)
1,000 VAC, 50/60 Hz for 1 min (between non-continuous contacts)
Vibration resistance
Destruction: 10 to 55 Hz, 0.75-mm single amplitude
Malfunction: 10 to 55 Hz, 0.5-mm single amplitude
Shock resistance
Destruction: 300 m/s
2
(approx. 30G)
Malfunction: 100 m/s
2
(approx. 10G)
Ambient temperature
Operating:
--10
"
C to 55
"
C (with no icing)
Storage:
--25
"
C to 65
"
C (with no icing)
Ambient humidity
Operating:
35% to 85%
Life expectancy
Mechanical: 10,000,000 operations min. (under no load at 1,800 operations/h)
Electrical:
100,000 operations min. (3 A at 250 VAC, resistive load at 1,800 operations/h)
Impulse withstand voltage
Between power terminals: 1 kV
Noise immunity
#
1.5 kV, square-wave noise by noise simulator (pulse width: 100 ns/1
%
s, 1-ns rise)
Static immunity
Destruction: 8 kV
Malfunction: 4 kV
Enclosure rating
IP20
Weight
Approx. 18 g
EMC
Emission Enclosure:
EN55011 Group 1 class A
Emission AC Mains:
EN55011 Group 1 class A
Immunity ESD:
EN61000-4-2: 4 kV contact discharge (level 2)
8 kV air discharge (level 3)
Immunity RF-interference:
ENV50140:
10 V/m (amplitude modulated, 80 MHz to
1 GHz) (level 3)
10 V/m (pulse modulated, 900 MHz)
Immunity Conducted Disturbance: ENV50141:
10 V (0.15 to 80 MHz) (level 3)
Immunity Burst:
EN61000-4-4: 2 kV power-line (level 3)
2 kV I/O signal-line (level 4)
Approved standards
UL508, CSA22.2 No. 14
Conforms to VDE 0435/P2021 (for built-in use)
Conforms to EN50081-2, EN50082-2