background image

 

 

TDDGT

 - 

Instruction Manual

 

7-Day Digital Geyser Timer (Internal Relay) 

 
 
 
 

 
Operating Instructions 

 

Apply 220V to Live (L) terminal and Neutral (N) terminal 
on timer. 

 

Push Clock button once. Program 1 is now set. 

 

Wait for 20 seconds, then push recessed Reset button. 
Timer will reset. 

 

For timer to operate automatically press Manual button 
until On Auto appears on screen. 

 

 

To operate timer manually press Manual button until On 
or Off appears on screen. 

SETTING DAY & TIME 

 

 

Push and hold Clock button. 

RECOMMENDED MUNICIPAL TIME SETTINGS 

 

Push D+ repeatedly to adjust Day. 

 

Timer 1: 04:00 ON – 06:00 OFF 

 

Push H+ repeatedly to adjust Hour. 

 

Timer 2: 11:00 ON – 14:00 OFF 

 

Push M+ to adjust Minute. 

 

Timer 3: 16:00 ON – 18:00 OFF 

 

Release Clock button. Time and Date set. 

 

Timer 4: 21:00 ON – 23:00 OFF 

 

        OR 
RECOMMENDED POWER UTILITIES TIMES 

 

21:00 ON – 06:00 OFF

 

 

PROGRAMMING TIMER 

WIRING 

 

Push P button once (Program 1 On appears.) 

 

Connect 220V to Live (L) terminal and Neutral (N) terminal 
on timer.  

 

Push D+ repeatedly until desired day is reached (various 
combinations of days are available). 

 

The Load must be connected to the Load terminal. 

 

Push H+ repeatedly until desired hour is reached. 

 

The Load terminal will be LIVE only when timer is on. 

 

Push M+ repeatedly until desired minute is reached. 

 

The Neutral of the Load must be connected to the 
appropriate Neutral bar and NOT the timer.  

 

Push P button once again (Program 1 Off appears). 

 

 

Push D+ repeatedly until desired day is reached (various 
combinations of days are available). 

 

 

Push H+ repeatedly until desired hour is reached. 

 

 

Push M+ repeatedly until desired minute is reached. 

 

 

 

WIRING DIAGRAM 

Line In  

 

Neutral  

 

Live In 

       

      Geyser  
      Circuit  
     Breaker 

 

      Live 

 

      Load Out 

 

 

 

Rated Voltage: 220-240V AC 

 

Max 20A (3500 Watts) 

 

16 Programmable Settings 

Resistive Load (Geyser) 

 

15-Day Backup Battery 

 

Max 10A (Inductive Load) 

 

IEC 60730 Rated 

 

DIN Rail Mounted 

Please note: 

 

All electrical installations should be done by a qualified electrician. 

 

The maximum current rating is 20 Amps. 

 

Resistive loads (geysers, under-floor heating and lights) 

 

Inductive loads (pool pump, air-conditioners).

 

TDDGT 

Timer 

[email protected]

Reviews: