background image

 

 

12

MV MX 

Model 

Function 

No. 

Set 

value

No. 

Set 

value 

Remarks 

Multi function input   

selection 1 

n050 1  C001  00 

 

Multi function input   

selection 2 

n051 2  C002  01 

 

Multi function input 

selection 3 

n052 3  C003  18 

 

Multi function input   

selection 4 

n053 5  C004  12 

 

Multi function input   

selection 5 

n054 6  C005  02 

 

Multi function input 

 selection 6 

n055 7  C006  03 

 

Multi function input 

 selection 7 

n056 10 

―――

 

―――

 

No setting is possible since the number of 

multi function inputs of MX is 6.     

Multi function output 

selection 1 

n057 0  C026  05 

 

Multi function output 

selection 2 

n058 1  C021  00 

 

Multi function output 

selection 3 

n059 2  C022  01 

 

Frequency reference gain 

n060 100 

C081 
C082 

100.0 
100.0 

C081: Gain adjustment at voltage input   

C082: Gain adjustment at current input   

Frequency reference bias 

n061 0 

A011 

A101 

0.0 
0.0 

A011: Bias adjustment at voltage input   

A101: Bias adjustment at current input.   

Analog frequency reference   

filter time constant   

n062 0.10  A016 

MV: Set    filter time constant 

MX: Set sampling frequency   

(Not used)   

n063 

―――

 

―――

 

―――

 

 

Frequency reference loss 

detection function   

selection 

n064 0 

―――

 

―――

 

 

Multi function analog 

output : output type 

selection  

n065 0 

―――

 

―――

 

 

Multi function analog output 

selection 

n066 0  C028  00 

 

Multi function analog output 

gain  

n067 1.00  b080  100 

 

Multi function analog 

voltage input gain 

n068 100 

―――

 

―――

 

 

Multi function analog 

voltage input bias 

n069 0 

―――

 

―――

 

 

Multi function analog 

voltage input: filter time 

constant  

n070 0.10 

―――

 

―――

 

 

Multi function analog current 

input gain 

n071 100 

―――

 

―――

 

 

Multi function analog current 

input bias 

n072 0 

―――

 

―――

 

 

Summary of Contents for 3G3MX-A2001

Page 1: ...1 3G3MV 3G3MX Migration guide...

Page 2: ...RCUIT TERMINAL 4 CONTROL CIRCUIT TERMINAL 5 THE DIFFERENCES ON TERMINAL SCREW AND WIRE SIZE BETWEEN MV AND MX 6 4 STANDARD BRAKING TORQUE AND MINIMUM CONNECTABLE RESISTANCE VALUE 8 5 PARAMETER TABLE 1...

Page 3: ...r of multi function analog input usable on the MX is one Change to MX is not possible if two analog inputs are used on the MV 4 The functions below are not available on the MX Frequency reference loss...

Page 4: ...dimensions of the MX drive are larger than the MV series Please note that the size value is larger than the MV depending on capacity The mounting screw position on 3G3MV AE002 AE004 A2002 to 2007 diff...

Page 5: ...MV MX Remarks R L1 R L1 S L2 S L2 T L3 T L3 AC power input terminal U T1 U T1 V T2 V T2 W T3 W T3 Motor output terminal B1 P 2 B2 RB Braking resistor connection terminal 1 1 DC reactor connection term...

Page 6: ...ent on the MV and MX drives The default value will display the multi function setting allocated on both MV and MX On the default setting the control terminals of S3 and S4 on MV have switched to the o...

Page 7: ...nd wire size differences between MV and MX Main circuit terminal size and electrical wire size Recommended wiring breaker and electromagnetic contactor will be same Control circuit terminal size and e...

Page 8: ...s 0 5mm 2 The length to signal line armor is 5 to 6mm and connect it as an electrical wire If stranded wire keep it from coming apart The max armor outer dimensions of signal line except alarm signal...

Page 9: ...in the shortest time From 60Hz on a single unit motor MX the average deceleration torque when deceleration in the shortest time From 50Hz on a single unit motor Braking resistor is not installed on in...

Page 10: ...10 bold Depending on cases please consider using a larger capacity drive Minimum connectable resistance value on each capacity Following is the braking options used on MX...

Page 11: ...selection at operator interruption n010 0 Maximum frequency n01 1 60 0 A004 60 0 Maximum voltage n012 200 0 A082 200 Maximum voltage frequency n013 60 0 A003 60 0 Middle output frequency n014 1 5 A04...

Page 12: ...pper frequency reference limit n033 100 A061 0 0 The default value of MX 0 0 shows limit function invalid Lower frequency reference limit n034 0 A062 0 0 Frequency reference select reference unit sele...

Page 13: ...081 C082 100 0 100 0 C081 Gain adjustment at voltage input C082 Gain adjustment at current input Frequency reference bias n061 0 A01 1 A101 0 0 0 0 A011 Bias adjustment at voltage input A101 Bias adju...

Page 14: ...umbers of retry is fixed at 3 Jump frequency 1 n083 0 00 A063 0 0 Jump frequency 2 n084 0 00 A065 0 0 Jump frequency 3 n085 0 00 A067 0 0 Jump width n086 0 00 A064 A066 A068 0 5 MV set output frequenc...

Page 15: ...ng at same frequency on trip retry function Torque compensation gain n103 1 0 A046 1 0 Torque compensation primary delay time constant n104 0 3 Torque compensation excitation loss n105 Varies with cap...

Page 16: ...A071 00 Detection value adjustment gain n129 1 00 A075 1 00 MV Adjust input level of target value MX Set percentage of feedback value and display it on monitor d004 Proportional gain P n130 1 0 A072...

Page 17: ...t used n147 n148 Pulse train input scale n149 2500 Multi function analog output pulse train frequency selection n150 0 RS 422 485 communication time over detection selection n151 0 C076 C077 02 0 00 C...

Page 18: ...sed n165 Input open phase detection level n166 0 Input open phase detection time n167 0 Output open phase detection level n168 0 Output open phase detection time n169 0 0 Enter command operation selec...

Page 19: ...0 10 0 AE022 3 8 11 0 5 0 No decrease of rating Single phase 200V AB037 6 7 17 5 7 5 16 5 A2001 0 3 0 8 A2002 0 6 1 6 A2002 0 6 1 6 A2004 1 1 3 0 A2004 1 0 3 0 A2007 1 9 5 0 10 No decrease of rating A...