Introduction
SECTION 1
11
Item
CPM2C-S 3G3MV-P10CDT
Program area, read-only DM
area (including PLC Setup)
Flash memory backup
Flash memory backup
Unit with clock:
Internal battery backup (5-year
lifetime at 25°C, non-
replaceable)
Memory backup
Read/write DM area, HR
area, AR area, and counters
Internal battery backup (2-year
life-time at 25°C, replaceable)
Unit without clock: Capacitor
backup (10-day backup at
25°C)
CompoBus/S Master Functions
Up to 32 Slaves can be
connected and up to 256 I/O
points can be controlled.
---
DeviceNet Slave Functions
DeviceNet Remote I/O Link
Use up to 1,024 I/O points in
the I/O Link. Explicit Message
Communications Any PLC data
area can be accessed from the
Master.
---
Interrupt inputs (interrupt input mode)
2
2
Counter mode
Incrementing counter
Decrementing counter
Incrementing counter
Decrementing counter
Counter upper limit
2 kHz
2 kHz
SR 244 to SR 247
Contains counter PV.
Contains counter PV.
Method(s) to read counter
PV
Read SR 244 to SR247.
Execute PRV(62).
Read SR 244 to SR247.
Execute PRV(62).
Interrupt inputs
(counter mode)
Method to change counter
PV
Execute INI(61).
Execute INI(61).
One-shot mode
Yes
Yes
Interval timer
Scheduled interrupt mode
Yes
Yes
Setting the quick-response
function
PLC Setup
PLC Setup
INT(89) (Mask)
Not supported (ignored)
Not supported (ignored)
INT(89) (Read mask)
Reads mask status.
Reads mask status.
INT(89) (Clear)
Not supported (ignored)
Not supported (ignored)
Quick-response
inputs
Minimum pulse width
50
µ
s min.
50
µ
s min.
Count mode
Differential-phase (up/down)
mode
Pulse plus direction mode
Up/down pulse mode
Increment mode
Differential-phase (up/down)
mode
Pulse plus direction mode
Up/down pulse mode
Increment mode
Max. counter frequency
5 kHz in differential-phase
(up/down) mode
20 kHz in pulse plus direction
mode, up/down pulse mode,
and increment mode
5 kHz in differential-phase
(up/down) mode
20 kHz in pulse plus direction
mode, up/down pulse mode,
and increment mode
High-speed
counter
Counter PV range
–8,388,608 to 8,388,607 in
differential-phase (up/down)
mode,
pulse plus direction mode, and
up/down pulse mode
0 to 16,777,215 in increment
mode
–8,388,608 to 8,388,607 in
differential-phase (up/down)
mode,
pulse plus direction mode, and
up/down pulse mode
0 to 16,777,215 in increment
mode
Summary of Contents for 3G3MV-P10CDT-E
Page 2: ...3G3MV P10CDT PLC Option Unit User s Manual Revised June 2003 ...
Page 38: ...Unit Components and Specifications SECTION 2 2 1 4 Dimensions 68 128 55 25 ...
Page 43: ......
Page 85: ...Example Programs Appendix B 72 ...
Page 86: ...Example Programs Appendix B 73 ...
Page 87: ...Example Programs Appendix B 74 ...
Page 88: ...Example Programs Appendix B 75 ...
Page 90: ...Example Programs Appendix B 77 ...
Page 91: ...Example Programs Appendix B 78 ...
Page 97: ...Example Programs Appendix B B 4 9 Programs User_Parameter_Init 84 ...
Page 98: ...Example Programs Appendix B 85 ...
Page 99: ...Example Programs Appendix B User_Application Pos_Loop 86 ...
Page 100: ...Example Programs Appendix B 87 ...
Page 101: ...Example Programs Appendix B 88 ...
Page 102: ...Example Programs Appendix B 89 ...
Page 103: ...Example Programs Appendix B 90 ...
Page 104: ...Example Programs Appendix B 91 ...
Page 105: ...Example Programs Appendix B 92 ...
Page 106: ...Example Programs Appendix B 93 ...
Page 107: ...Example Programs Appendix B Pos_Home_Sequence 94 ...
Page 108: ...Example Programs Appendix B 95 ...
Page 109: ...Example Programs Appendix B 96 ...