H
Operation Specifications
Control input
Three photocoupler input terminals (24 VDC, 8 mA)
•
Forward/stop [SF]
•
Reverse/stop [SR]
•
Multi-function input [S1] (set in constant No. 06)
•
Multi-function input [S2] (set in constant No. 07)
•
Multi-function input [S3] (set in constant No. 08)
Note
When 3-wire sequence mode (constant No. 01 = “9”) is selected, the
terminals become as follows:
•
Run command [SF]
•
Stop command [SR]
•
Forward/reverse rotation command [S1]
Note
The standard Inverters are not provided with S2 and S3 terminals.
One analog input terminal (0 to 10 VDC or 4 to 20 mA)
•
Frequency reference input [Between FC and FR]
Control output
One SPDT relay contact output terminal [MA, MB]
(30 VDC and 1A; 250 VAC and 1A)
•
Multi-function contact output (set in constant No. 09)
One photocoupler input terminal [PA] (48 VDC, 50 mA)
•
Multi-function photocoupler output (set in constant No. 10)
Note
The standard Inverters are not provided with the multi-function photo-
coupler output.
Analog output
One analog voltage output [AM] (0 to 10 VDC, 2 mA)
•
Multi-functional analog output (Constant No. 44 is used to set the function
and constant No. 45 is used to set the multiplying factor.)
The output frequency or output current can be monitored. The Inverter is fac-
tory-set to output frequency monitoring.
Note
The standard Inverters are not provided with the multi-function analog
output.
Specifications
Chapter 4
Summary of Contents for 3G3EV-A2001-CUE
Page 8: ......
Page 11: ...Chapter 1 Getting Started 1 1 Items to be Checked when Unpacking 1 2 Precautions 1...
Page 14: ...Chapter 2 Overview 2 1 Features 2 2 Nomenclature 2...
Page 19: ...Chapter 3 Design 3 1 Installation 3 2 Wiring 3...
Page 41: ...Chapter 4 Specifications 4 1 Specifications of Main Unit 4 2 Specifications of Noise Filter 4...
Page 48: ...4 8 D 3G3EV PNF2003A YN PNF2010A YN Two 5 0 dia max 1 Specifications Chapter 4...
Page 49: ...4 9 D 3G3EV PNF2020A YN 5 0 dia 5 93 1 118 1 128 2 74 2 56 1 74 max Specifications Chapter 4...