4. Verify that both of the RX2 and TX2 LEDs on the Front Panel are either green or red. If they
are not, verify steps 1 and 2. If the problem persists, see your System Administrator or call
the Omnitronix Technical Support group.
Accessing the Command Line
1. Connect to COM1 with a serial terminal emulation program at 19200 baud, 8N1.
2. Once connected to the DL50 via COM1, verify that the CTS2 LED on the front of the DL50
is lit red.
3. Type SETUP and press <ENTER>. You should be presented with a status screen similar to
the following.
Data-Link DL50 1.00 Unit Serial # : 510002168
Unit ID : Data-Link
Date : THU 01/06/00 % Full alarm : OFF
Time : 13:40:10 No Data Alarm 1: OFF
Memory : 256K No Data Alarm 2: OFF
% Full : 01% Release mode : LINE
Modem : NONE Duplex : FULL
Network : Yes Password : ON
IP Add : 192.168.105.12 Compress : OFF
MAC Add : 00:11:C3:A1:2F:0F
-----------------------------------------------------------
Port 1 Port 2
Baud Rate 19200 19200
Parity, etc. 8N1 8N1
File Records 00000000 00000005
File Bytes 00000000 00000026
File % Full 00% 00%
ASCII/Binary ASCII ASCII
Handshake XON/XOFF XON/XOFF
File Wrap OFF OFF
Alarm Filter NONE NONE
If the status screen appears, the DL50 is successfully connected and ready for use. The next
section will continue by covering network setup.
1.3 - Network Setup
Setup
1. Access the setup menu by typing SETUP and pressing <ENTER>.
2. Select the Network Settings branch.
3. Select the IP Address option and then type in the static IP address to be assigned to the unit.
4. If necessary, select Subnet Mask and enter the appropriate value.
5. If the DL50 is to be used on a WAN, select Router Address and then type in the IP address of
the router.