- Command Reference
Manual Rev. 1.01
Page 43
Command: RETRSET
Function: GET USER SETTINGS
Syntax: RETRSET
[X|Y|A|B]
Retrieves non-default settings from the unit, using Xmodem or ASCII transfer. Arguments 'Y' and
'B' cause ALL settings to be retrieved, using Xmodem or ASCII (settings retrieved this way not
necessarily compatible with other product versions).
Command: SETUP
Function: ENTER SETUP MENU
Syntax:
SETUP
Enters Setup menu.
6.4 - System Commands
The following settings are accessible only with administrative privileges.
Command: BYPASS
Function: ACCESS DEVICES CONNECTED SERIALLY
Syntax:
BYPASS [
port number
]
Provide pass-through operation between the console port and the specified port. If no port is
specified, uses the port associated with the current ACCESS file.
Command: COLDSTART
Function: COLD BOOT UNIT
Syntax:
COLDSTART
Resets the same settings as the DEFAULT command and then reboots the unit.
Command: FTEST
Function: TEST FLASH MEMORY
Syntax:
FTEST
Destructive test of CRDB flash memory. All record data is lost, and any active polling sessions
will fail. Records are NOT recoverable.
WARNING: FTEST only requires confirmation if "Confirm Before Deletion" menu option is
enabled.
Command: PUSHTEST
Function: TEST FTP PUSH
Syntax:
PUSHTEST
Attempt to connect to the FTP server specified in FTP push settings, and display the results of the
attempt.