the remote ports. If “Forward” is displayed, the remote partner is forwarding non-OAMPDUs network
frames to the
higher
sublayer. If “Loopback” is displayed, the remote partner is looping back non-
OAMPDUs network frames. If “Discard” is displayed, the remote partner is discarding non-OAMPDUs
network frames. If “Unknown”, the Parser Action state of the remote partner is indeterminate.
•
Critical Event - Indicates the Critical Event state (“Yes”, “No” or “Unknown”) of the remote partner. If
“Yes” is displayed, the local device has detected a Critical Event. If “No”, the local device has not
detected a critical event. If “Unknown,” the Critical Event status of the remote partner is indeterminate.
•
Link Fault - Indicates the remote partner has detected a fault in the receive direction (“Yes”, “No” or
“Unknown”). If “Yes” is displayed, the receive link is down. If “No”, the receive link is up. If
“Unknown,” the link fault status is indeterminate.
•
OAM Mode - Indicates the OAM mode (“Active” or “Passive”) of the remote partner.
•
Supports - Indicates the supported options (Variable Access “Var”, Link Event Notification “Event”,
Loopback “LB”, or blank if no options are supported) of the remote partner.
•
OUI - Indicates the three hex byte IEEE organizational specific identifier (or blank if unknown) of the
remote partner.
802.3ah parameters can be accessed by selecting options
7
from the
Port
configuration screen. The fiber
(port 1) configuration screen is displayed.
PI
SA
802.3ah Control - iConverter 2GXM
iConverter, Serial Agent
Identifier -
Chassis Number = 1 Slot Number = 1 Model Number = 8999-0
Port # = 1
1: 802.3ah OAM State
Disabled
Local Status
2: OAM Mode
Passive
Discovery State
Disabled
3: Loopback Mode
Disabled
Multiplexer State
Forward
4: Loopback Timeout
30 sec
Parser Action
Forward
5: Unidirectional Mode
Not Available
Remote Status
Discovery State
Unknown
Critical Event
No
Link Fault
No
Multiplexer State
Unknown
Parser Action
Unknown
Mode
Unknown
Supports
Unknown
OUI:
Unknown
Enter, Previous Screen (0), (n)ext page, (H)elp, E(x)it >
To configure the 802.3ah parameters for the Port 2, type an
n
and press <ENTER>.
Page 31