Page 18
3.4.3
Management Processor VLAN Support
The 2GXM Management Processor can independently transmit and receive Management Data with an
IEEE 802.1Q tag. To enable and configure this feature, type
9
from the
Management Options
screen to
access the
Other Networking Features
screen.
PI
SA
Management Options
iConverter, Serial Agent
Network Management
1: Chassis and Module Management
2: Set Module Identifier
Management Module Preferences
3: IP and Control Preferences
4: SNMP Preferences
5: Abandon Preference Changes
6: Save Preference Changes
7: Restore to Factory Defaults
8: Restart Management Module
9: Other Networking Features
Management Module Maintenance
10: Firmware Update
11: Set Date/Time
IP Address = 192.168.1.220
Chassis Number = 1
Enter Choice, (H)elp, E(x)it > 9
PI
SA
Other Networking Features Screen
iConverter, Serial Agent
1: Enable/Disable DHCP Client
Disabled
2: Enable/Disable Keep Alive Trap
Disabled
3: Keep Alive Trap interval (10-600 secs)
10
4: Enable/Disable SW1 Switch Block
Enabled
5: Serial Baud Rate
57600 bps
6: Enable/Disable VLAN Support
Disabled
7: VLAN ID (0-4095)
2
8: VLAN Priority (0-7)
7
Enter Choice, Management Options Screen(0), (H)elp, E(x)it >
To configure the VLAN management ID, select option
7
. To configure the priority setting for the VLAN
management channel, select option
8.
To enable or disable VLAN management support, select option
6.
Once VLAN support is enabled, IP management support will only be accessible using the configured
VLAN ID.
To save the new values, select
0
and press
<ENTER>
to return to the
Management Options
screen, then
select
6
and press
<ENTER>
to
Save Preference Changes
.