PI
SA
Management Options
iConverter, Serial Agent
Network Management
1: Chassis and Module Management
2: Set Module Identifier
Management Module Preferences
3: IP and Control Preferences
4: SNMP Preferences
5: Abandon Preference Changes
6: Save Preference Changes
7: Restore to Factory Defaults
8: Restart Management Module
9: Other Networking Features
Management Module Maintenance
10: Firmware Update
11: Set Date/Time
IP Address = 192.168.1.220
Chassis Number = 1
Enter Choice, (H)elp, E(x)it > 9
PI
SA
Other Networking Features Screen
iConverter, Serial Agent
1: Enable/Disable DHCP Client
Disabled
2: Enable/Disable Keep Alive Trap
Disabled
3: Keep Alive Trap interval (10-600 secs)
10
4: Enable/Disable SW1 Switch Block
Enabled
5: Serial Baud Rate
57600 bps
6: Enable/Disable VLAN Support
Disabled
7: VLAN ID (0-4095)
2
8: VLAN Priority (0-7)
7
Enter Choice, Management Options Screen(0), (H)elp, E(x)it >
To enable DHCP client, select
1
at the
Other Networking Features
screen and follow the screen prompts
to enable DHCP.
To save the new values, select
0
and press <
ENTER
> to return to the
Management Options
screen, then
select
6
and press <
ENTER
> to
Save Preference Changes
.
3.4.1.3
Setting the Chassis Number and Name
A Chassis Name, or sysName, can be assigned for identification of the 2GXM in the SNMP client. The
name can be any 1-32 character alphanumeric string.
The Chassis Number can remain as 1 (factory default) when the 2GXM is installed without an
iConverter
NMM
in the same chassis. When the 2GXM is installed in the same chassis as an NMM, then the 2GXM must be set
to the Chassis Number of the NMM.
To set the Chassis Number, select
4
at the
IP and Control Preferences
screen, press
<ENTER>
and follow
the instructions to enter the chassis number.
To set the Chassis Name, select
5
at the
IP and Control Preferences
screen, press
<ENTER>
and follow
the instructions to enter the chassis name.
Page 13