![Omnicomm Light 2.0 Installation Manual Download Page 16](http://html1.mh-extra.com/html/omnicomm/light-2-0/light-2-0_installation-manual_739213016.webp)
[email protected] | Installation manual Omnicomm 2.0 terminals v2.2
7
.16 | 16
“Closing duration, s” – specify the time during which the output must be switched on. Possible values: from
0.1 to 9.9 s.
“Opening duration, s” – specify the time before a recurrent output switching on. Possible values: from 0.0 to 29.9 s.
Example 1. The following values are set:
State – “In geofence”,
Number of cycles “closed-open” - 5.
If the VH is inside the geofence, the output will go on-o
ff
5 times. Switching the output on-o
ff
(5 times) will
be repeated until the VH leaves the geofence.
Example 2. The following values are set:
State – “Out of geofences”, “GPS”,
Number of cycles “closed-open” – “Permanently”.
If the VH is outside the geofence and GPS-module data are valid, the output will be on until the VH enters
the geofence or GPS data terminate.
4.1
6
GEOFENCING
Omnicomm 2.0 Terminals (excluding Smart 2.0) provide for geofencing to switch on controlled outputs.
Open the tab “Geofences” in the screen “Settings”:
“Number of points to con
fi
rm location inside/outside geofence” – specify the number of sequentially
determined VH coordinates required to track the VH location inside or outside the geofence. The period of
coordinate determining is 1 sec. Possible values: from 1 to 10.
To add a geofence, press the button “Import” and select the xml-
fi
le with geofence settings.
Maximum number of geofences is 6. Maximum number of angular points is 24.
4.1
7
CONNECTING ADDITIONAL EQUIPMENT TO RS
-
485 AND RS
-
232 INTERFACES
Connection of additional equipment (CAN-Log, PP-01 passenger
fl
ow sensors, DV-1 driver display,
JPEG camera, receiving data from information bus J1708 of the vehicle, reception and transmission of
navigational information in accordance with NMEA standard) is established to the RS-485 and RS-232
interfaces. If necessary, it is recommended that you use RS-232/RS-485 converter.
Connection of optional equipment, such as the RS-232 interface to the Omnicomm Optim 2.0, Pro
fi
2.0
and Pro
fi
2.0 WiFi Terminals, is conducted in accordance with Figure 85, when utilising the RS-232/RS-485
converter, Figure 86.
Connection of additional equipment, such as the RS-485 interface to the Omnicomm Optim 2.0, Pro
fi
2.0
and Pro
fi
2.0 WiFi Terminals, is conducted in accordance with Figure 88, and when utilising the RS-232/RS-
485 converter, Figure 89.
4.1
8
FUSE INSTALLATION
Fuses are designed to protect the on-board network of the vehicle from electrical system short-circuits in
cases of breakdown of product wiring.
Connect the product wires to the fuse holders and in close proximity to the signal sources (Figures 53–55).