Connections and Interfaces
39
5.2.7.2
LL out 1-6 (Low Level Outputs 1-6)
The SELV interface connector "LL out 1 - 6" holds two independent
generator triples. These six high accuracy analog signal sources can serve
to either control an external amplifier or to directly provide small signal
outputs.
In addition, a serial digital interface is available that transmits control and
monitor functions between the
CMC 356
and the external amplifiers.
Supported devices are
CMA 156
,
CMA 56
1
,
CMS 156
,
CMS 251
1
and
CMS 252
1
.
The low level outputs are short-circuit-proof and continually monitored for
overload.
Connect the external amplifier to the
CMC 356
low level outputs. Use the
connecting cable that was supplied with the amplifier.
For more detailed information please refer to the technical data section
6.3.5, "Low Level Outputs "LL out" for External Amplifiers" on page 54.
5.2.7.3
LL out 7-12 (Low Level Outputs 7-12) - Option "LLO-2"
The SELV interface connector "LL out 7 - 12" is optionally available for the
CMC 356
test set.
The outputs 7-12 extend the low level outputs 1-6 by two more independent
generator triples. Outputs 7-12 are technically identical to outputs 1-6 as
described above.
For more detailed information please refer to the technical data section 6.12,
"Option LLO-2 (Low Level Outputs)" on page 94.
Overload Warning Flagged in the Software
When a low level output is overloaded, a corresponding warning message
appears on the user interface of the OMICRON
Test Universe
software.
1
These products are not available anymore.
LL out 1 - 6
LL out 7 - 12
Summary of Contents for CMC 356
Page 1: ...CMC 356 Reference Manual ...
Page 40: ...CMC 356 Reference Manual 40 ...
Page 104: ...CMC 356 Reference Manual 104 ...
Page 108: ...Open Source License Information 108 ...
Page 110: ...Support 110 ...