background image

15

Section 9 - Receiver Connection Cont.

RX

PWR

STATUS

24 Vdc

POWER SUPPLY

4-20 mA ANALOG OUTPUT

INTO PLC OR DATA LOGGER

1

2

3

4

5

6

7

8

+

+

10

9
8
7
6
5
4
3

2
1

4-20 mA Output Example

1

2

3

4

5

6

7

8

10

9
8
7
6
5
4
3
2
1

+

12-24 Vdc

POWER

SUPPLY

ALARM

RELAY

200 mA MAX

1N4004*

+

RX

PWR

STATUS

Alarm Example, System Powered

1

2

3

4

5

6

7

8

10

9
8
7
6
5
4
3
2
1

+

12-24 Vdc

POWER

SUPPLY

0-24 Vdc

POWER

SUPPLY

ALARM

RELAY

200 mA MAX

1N4004*

+

RX

PWR

STATUS

+

Alarm Example, External Power Supply

+

0-5 Vdc ANALOG OUTPUT

INTO PLC OR DATA LOGGER

+

RX

PWR

STATUS

12 - 24 Vdc
FROM HOST
INSTRUMENT

1

2

3

4

5

6

7

8

10

9
8
7
6
5
4
3
2
1

Voltage Output Example

*Required for magnetic relays. Not required for solid state relays.

Receiver Connection

9

Summary of Contents for UWRTD Series

Page 1: ...used 1 as a Basic Component under 10 CFR 21 NRC used in or with any nuclear installation or activity or 2 in medical applications or used on humans Should any Product s be used in or with any nuclear...

Page 2: ...ConnectorTM Wireless Thermocouple RTD Connector Transmitter Receiver e mail info omega com For latest product manuals www omegamanual info Shop online at omega com For complete product manual www ome...

Page 3: ...1 Introduction 1 Section 2 Product Labels 2 Section 3 Setup Instructions 3 Section 4 Product Labels 5 Section 5 Transmitter Operation 6 Section 6 Connector Operation 7 Section 7 Battery Installation 9...

Page 4: ...Setup Instructions 3 UWTC UWRTD Setup Procedure 3 1 Install Software 3 2 Install USB Drivers 3 3 Configure Transmitter 3 4 Configure Receiver 4 Section 4 Software 5 Section 5 Transmitter Connector Op...

Page 5: ...and can transmit simultaneously with your UWTC unit Never install UWTC connector transmitters within 20 cm or less from each other Never install and or operate your UWTC connector transmitter closer...

Page 6: ...ved including interference that may cause undesired operation FCC ID OUR XBEEPRO IC 4214A XBEEPRO omega com PATENTS PATENTS PENDING F WIRELESS INDUSTRIAL TRANSMITTER 2 4 GHz OMEGA ENGINEERING INC Stam...

Page 7: ...his is normal You should repeat the steps outlined here twice After the second driver is installed you should then get the New Hardware Ready For Use notice 3 Configure Transmitter Complete the follow...

Page 8: ...r receivers complete the following procedure Your UWTC REC receiver must be connected to a USB port on your PC a Launch the UWTC REC setup utility program on your PC You can access it through the Prog...

Page 9: ...g that is being measured by your thermocouple or RTD sensor Ambient This is the actual ambient temperature connector inside the body of your Connector Transmitter If the unit is exposed to temperature...

Page 10: ...TOR LOW BATT PRESS SETUP PRESS ON OFF UWRTD 3 2 4 1 7 5 6 8 1 RTD WIRING DETAIL 2 3 4 TX UNIVERSAL WIRELESS THERMOCOUPLE CONNECTOR LOW BATT PRESS SETUP PRESS ON OFF UWTC 3 2 4 1 7 5 6 8 1 ON OFF Butto...

Page 11: ...NB9 UWTC NB9 NEMA UWTC 2 NEMA Thermocouple Version Industrial Probe RTD Versions UWRTD NB9 UWRTD NB9 NEMA UWRTD 2 NEMA RTD Version TC INPUT NOT USED TC INPUT 3 4 5 6 1 2 3 4 5 6 1 2 RTD WIRING DETAIL...

Page 12: ...will blink one time every 5 seconds 2 Low Battery Low Batt Red Indicator Light The red indicator light marked Low Batt on the front of the connector transmitter will turn on when the battery reaches...

Page 13: ...o screws that secure the main circuit board from the probe head assembly B Tilt the front of the circuit board just high enough to allow you to unplug the connector that attaches the battery assembly...

Page 14: ...ce that may cause undesired operation FCC ID OUR XBEEPRO IC 4214A XBEEPRO F 2 3 1 1 2 3 4 5 6 7 8 9 UWTC RPT1 SIDE VIEW ANTENNA USB I O 12 16 Vdc UWTC SERIES WIRELESS TRANSCEIVER OMEGA ENGINEERING INC...

Page 15: ...de in USA Omega Engineering Inc Stamford CT 06907 4 5 POWER TRANSMIT NETWORK LINK ACTIVITY 6 3 2 2 1 UWTC REC3 1 Antenna 2 Indicator Lights 3 Power LED 4 DC Power Jack 5 Reset 6 Ethernet Connection RJ...

Page 16: ...device must accept any interference received including interference that may cause undesired operation FCC ID OUR XBEEPRO IC 4214A XBEEPRO 4 UWTC REC1 NEMA 1 Antenna 2 USB NEMA 4X Connector Sealing Ca...

Page 17: ...nk each time the receiver receives incoming data from one of your connector transmitters 3 Standby SB Yellow Indicator Light The yellow indicator light marked SB on the front of the receiver will blin...

Page 18: ...3 ANALOG OUTPUT 2 ANALOG OUTPUT 1 ANALOG OUTPUT 4 ANALOG OUTPUT 3 ANALOG OUTPUT 2 ANALOG OUTPUT 1 RX PWR STATUS 1 2 3 4 5 6 7 8 10 9 8 7 6 5 4 3 2 1 Analog Output Connections 1 2 3 4 5 6 7 8 10 9 8 7...

Page 19: ...A MAX 1N4004 RX PWR STATUS Alarm Example System Powered 1 2 3 4 5 6 7 8 10 9 8 7 6 5 4 3 2 1 12 24 Vdc POWER SUPPLY 0 24 Vdc POWER SUPPLY ALARM RELAY 200 mA MAX 1N4004 RX PWR STATUS Alarm Example Exte...

Page 20: ...UIRED FOR MAGNETIC RELAYS NOT REQIRED FOR FOR SOLID STATE RELAYS OR MAGNETIC RELAYS WITH INTERNAL DIODE 0 24 VDC POWER SUPPLY 8 7 6 4 5 3 2 1 9 DRIVING A HIGH IMPEDANCE INPUT PULL HIGH DRIVE LOW J4 HI...

Reviews: