7.1.1.1 Digital Measurement Types
The Digital interface provides a measurement dependent on the input range/type selected. The units of
measure may be changed by the user.
Sensor Type
Measurement
SI Derived Units
Measurement
0x18
DIN
DIN
DIN (Digital Inputs)
0x19
FREQUENCY (RATE)
Hz
RATE
0x1a
PUSLE WIDTH
msec
PULSE WIDTH
0x1b
DUTY CYCLE
%
DUTY CYCLE
0x1d
COUNTER
CNT
COUNTER
7.1.1.2 Digital Data Type/Format
Digital Data Type/Format
7
6
5
4
3
2
1
0
Smart
Sensor
Writeable
Factory
Calibrate
Reserved
Data Type
0
1
0
0
6 == Floating point
7.1.1.2.1 Data Type
The 4-bit Data Type field determines the type of data of the specific sensor.
7.1.1.2.2 Factory Calibrate
No Factory calibration is used on the digital pulse inputs.
7.1.1.2.3 Writeable
The writeable bit is set, indicating that the sensor values may be overwritten. This allows values to
be preset, such as setting a counter value to 0.
7.1.1.3 Digital Configuration
Digital Configuration
7
6
5
4
3
2
1
0
Available Assigned
Apply
Scaling
Lock
Sensor Range / Type
0
0
?
?
(See Below)
7.1.1.3.1 Sensor Range / Type
Range / Type
Measurement
Type
Units of
Measure
Signals
DIO2
DIO1 **
DIO0
0x00
DIO
0x18
DIN
INPUT 2
INPUT 1
INPUT 0
0x01
RATE
0x19
Hz
RESET
ENABLE
PULSE
0x02
PULSE WIDTH
0x1a
msec
RESET
ENABLE
PULSE
0x03
DUTY CYCLE
0x1b
&
RESET
ENABLE
PULSE
0x05
COUNTER
0x1d
CNT
RESET
ENABLE
PULSE
** When configured for Mixed-mode operation (Digital pulse + Process) the DIN1 signal is used for the
Process input signal. The Pulse Delay and Up/Down counter functions are not available.