34

Installation and Maintenance

(3) The water outlet Can't be placed in water in order to drain 
smoothly.(As show in Fig.27)

Liquid valve

Gas valve

Refrigerant charging

vent
Nut of refrigerant
Charging vent

Vacuum pump

Piezometer

Valve cap

Lo

Hi

Inner hexagon

spanner

Open

Close

The drain hose can't be fluctuant

The drain hose

can't be fluctuant

The water 

outlet can't be

fluctuant

The water outlet 

can't be placed

in water

1. Use Vacuum Pump

(1) Remove the valve caps on the liquid valve and gas valve 
and the nut of refrigerant charging vent.
(2) Connect the charging hose of piezometer to the refrigerant 
charging vent of gas valve and then connect the other charging 
hose to the vacuum pump.
(3) Open the piezometer completely and operate for 10-15min 
to check if the pressure of piezometer remains in -0.1MPa.
(4) Close the vacuum pump and maintain this status for 1-2min 
to check if the pressure of piezometer remains in -0.1MPa. If 
the pressure decreases, there may be leakage.
(5) Remove the piezometer, open the valve core of liquid valve 
and gas valve completely with inner hexagon spanner.
(6) Tighten the screw caps of valves and refrigerant charging 
vent.(As show in Fig.28)

1. Check after Installation

Check according to the following requirement after finishing 
installation.

2. Leakage Detection

(1) With leakage detector:
Check if there is leakage with leakage detector.
(2) With soap water:
If leakage detector is not available, please use soap water for 
leakage detection. Apply soap water at the suspected position
and keep the soap water for more than 3min. If there are air 
bubbles coming out of this position, theres a leakage.

3

.7 Vacuum Pumping and Leak 

Detection

3

.8 Check after Installation and 

Test Operation

Fig.26

Fig.27

Fig.28

(1) The through-wall height of drain hose shouldnt be higher 
than the outlet pipe hole of indoor unit.(As show in Fig.25)
(2) Slant the drain hose slightly downwards. The drain hose 

Can't be curved, raised and fluctuant, etc.(As show in Fig.26)

Note:

The drain hos

can't raise

upwards

Fig.24

Fig.25

2. Test Operation

(1) Preparation of test operation

● The client approves the air conditioner installation.
● Specify the important notes for air conditioner to the client.

(2) Method of test operation

● Put through the power, press ON/OFF button on the remote

controller to start operation.

● Press MODE button to select AUTO, COOL, DRY, FAN and

HEAT to check whether the operation is normal or not.

● If the ambient temperature is lower than 16

, the air

conditioner Can't start cooling.

NO.

Items to be checked

Possible malfunction

1 Has the unit been 

installed firmly?

The unit may drop, shake or 

emit noise.

2 Have you done the 

refrigerant leakage test?

It may cause insufficient cooling 

(heating) capacity.

3 Is heat insulation of 

pipeline sufficient?

It may cause condensation and 

water dripping.

4

Is water drained well?

It may cause condensation and 

water dripping.

5

Is the voltage of power 

supply according to the 

voltage marked on the 

nameplate?

It may cause malfunction or 

damage the parts.

6

Is electric wiring and 

pipeline installed 

correctly?

It may cause malfunction or 

damage the parts.

7 Is the unit grounded 

securely?

It may cause electric leakage.

8 Does the power cord 

follow the specification?

It may cause malfunction or 

damage the parts.

9 Is there any obstruction 

in air inlet and air outlet?

It may cause insufficient cooling 

(heating) capacity.

10

The dust and 

sundries caused 

during installation are 

removed?

It may cause malfunction or 

damaging the parts.

11

The gas valve and liquid 

valve of connection pipe 

are open completely?

It may cause insufficient cooling 

(heating) capacity.

12

Is the inlet and outlet 

of piping hole been 

covered?

It may cause insufficient cooling 

(heating) capacity or waster 

eletricity.

U-shaped curve

Wall

Drain hose

Summary of Contents for OTEC ICHQ Series

Page 1: ...IEWQ ICHQ Series High Wall Inverter Installation Manual ...

Page 2: ... Maintenance 2 3 Installation 5 3 1 Installation Dimension Diagram 5 3 2 Installation Parts checking 7 3 3 Selection of Installation Location 7 3 4 Requirement For Electric Connection 7 3 5 Installation of Indoor Unit 7 3 6 Installation of Outdoor Unit 10 3 7 Vacuum Pumping and Leak Detection 11 3 8 Check after Installation and Test Operation 11 ...

Page 3: ...1 Technical Information 1 Summary Part Ⅰ Technical Information Indoor Unit Outdoor Unit IEWQ036J3A RWI100 ICHQ036J3A RLH100 Remote Controller ...

Page 4: ...ithout plug an air switch must be installed in the circuit The air switch should be all pole parting and the contact parting distance should be more than 3mm 12 Make sure all wires and pipes are connected properly and the valves are opened before energizing 13 Check if there is electric leakage on the unit body If yes please eliminate the electric leakage 14 Replace the fuse with a new one of the ...

Page 5: ...ed 4 If there is refrigerant leakage please take sufficient measure to minimize the density of refrigerant 5 Never touch the refrigerant piping or compressor without wearing glove to avoid scald or frostbite Refrigerant Safety Precautions Improper installation may lead to fire hazard explosion electric shock or injury Installation Safety Precautions connection pipe is not yet connected air will be...

Page 6: ... 4 Electroprobe 7 Electronic leakage detector 10 Pipe pliers pipe cutter 2 Screw driver 5 Universal meter 8 Vacuum pump 11 Pipe expander pipe bender 3 Impact drill drill head electric drill 6 Torque wrench open end wrench inner hexagon spanner 9 Pressure meter 12 Soldering appliance refrigerant container ...

Page 7: ...cm At least 15cm At least 250cm Space to the wall S p a c e t o t h e o b s t r u c t i o n r o o l f e h t o t e c a p S Space to the obstruction Drainage pipe Space to the wall Space to the obstruction Space to the obstructio Space to the obstruction A t l e a s t 3 0 0 c m At least 50cm At least 200cm At least 30cm At least 30cm At least 50cm ...

Page 8: ...t Make the bound pipes pass through the wall hole and then connect outdoor unit Neaten the pipes Vacuum pumping and leakage detection Check after installation and test operation Finish installation Note this flow is only for reference please find the more detailed installation steps in this section Select outdoor unit installation location Install the support of outdoor unit select it according to...

Page 9: ...ble Air switch should be included magnet buckle and heating buckle function it can protect the circuit short and overload Caution please do not use the fuse only for protect the circuit 1 Choosing Installation Iocation Recommend the installation location to the client and then confirm it with the client 2 Install Wall mounting Frame 1 Hang the wall mounting frame on the wall adjust it in horizonta...

Page 10: ...eter of Φ70mm on the selected outlet pipe position In order to drain smoothly slant the piping hole on the wall slightly downward to the outdoor side with the gradient of 5 10 As show in Fig 2 Note Insulating pipe Torque wrench Open end wrench Indoor pipe Pipe Union nut Union nut Pipe joint Pipe Hex nut diameter mm Tightening torque N m Φ6 15 20 Φ9 52 30 40 Φ12 45 55 Φ16 60 65 Φ19 70 75 Refer to t...

Page 11: ...llation when binding them When binding to a certain degree separate the indoor power and then separate the drain hose As show in Fig 15 3 Bind them evenly 4 The liquid pipe and gas pipe should be bound separately at the end 2 Make the power connection wire go through the cable cross hole at the back of indoor unit and then pull it out from the front side As show in Fig 12 3 Remove the wire clip co...

Page 12: ...show in Fig 20 4 Connect Indoor and Outdoor Pipes 1 Remove the screw on the handle and valve cover of outdoor unit and then remove the handle and valve cover As show in Fig 21 2 Remove the screw cap of valve and aim the pipe joint at the bellmouth of pipe As show in Fig 22 3 Pretightening the union nut with hand 4 Tighten the union nut with torque wrench Fig 18 Fig 19 Fig 20 Fig 21 Fig 22 1 After ...

Page 13: ...uldnt be higher than the outlet pipe hole of indoor unit As show in Fig 25 2 Slant the drain hose slightly downwards The drain hose Can t be curved raised and fluctuant etc As show in Fig 26 Note The drain hos can t raise upwards Fig 24 Fig 25 2 Test Operation 1 Preparation of test operation The client approves the air conditioner installation Specify the important notes for air conditioner to the...

Page 14: ...OMEGA IEWQ HQ High Wall Inverter Installation Manual IEWQ CHQ I3A IM1R0622 info otecomega com www otecomega com info otecomega com www otecomega com ...

Reviews: