30

Installation and Maintenance

No.

Name

No.

Name

1

Indoor unit

8

Sealing gum

2

Outdoor unit

9

Wrapping tape

3

Connection pipe

10

Support of outdoor 
unit

4

Drainage pipe

11

Fixing screw

5

Wall-mounting 
frame

12

Drainage plug(cooling 
and heating unit)

6

Connecting 
cable(power cord)

13

Owners manual, 
remote controller

7

Wall pipe

1. Safety Precaution

(1) Must follow the electric safety regulations when installing 
the unit.
(2) According to the local safety regulations, use qualified 
power supply circuit and air switch.
(3) Make sure the power supply matches with the requirement 
of air conditioner. Unstable power supply or incorrect wiring 

may result in electric shock,fire hazard or malfunction. Please 

install proper power supply cables before using the air 
conditioner.

(4) Properly connect the live wire, neutral wire and grounding 
wire of power socket.
(5) Be sure to cut off the power supply before proceeding any 
work related to electricity and safety.

(6) Do not put through the power before finishing installation.

(7) If the supply cord is damaged, it must be replaced by the 

manufacturer, its service agent or similary qualified persons in 

order to aviod a hazard.
(8) The temperature of refrigerant circuit will be high, please 
keep the interconnection cable away from the copper tube.
(9) The appliance shall be installed in accordance with national 
wiring regulations.

3

.2 Installation Parts-checking 

3

.3 Selection of Installation Location

3

.4 Requirement For Electric Connection 

3

.5 Installation of Indoor Unit

Air-conditioner Air switch capacity

36K

25A

1.Please contact the local agent for installation.

2.Dont use unqualified power cord.

2. Grounding Requirement:

(1) The air conditioner is first class electric appliance. It must 

be properly grounding with specialized grounding device 
by a professional. Please make sure it is always grounded 
effectively, otherwise it may cause electric shock.
(2) The yellow-green wire in air conditioner is grounding wire, 
which Can't be used for other purposes.
(3) The grounding resistance should comply with national 
electric safety regulations.
(4) The appliance must be positioned so that the plug is 
accessible.
(5) An all-pole disconnection switch having a contact separation 

of at least 3mm in all poles should be connected in fixed wiring.

(6) Including an air switch with suitable capacity, please note    
the following table. Air switch should be included magnet 
buckle and heating buckle function, it can protect the circuit-
short and overload. (Caution: please do not use the fuse only 
for protect the circuit)

1. Choosing Installation Iocation

Recommend the installation location to the client and then 

confirm it with the client.

2. Install Wall-mounting Frame

(1) Hang the wall-mounting frame on the wall; adjust it in 

horizontal position with the level meter and then point out the 

screw fixing holes on the wall.
(2) Drill the screw fixing holes on the wall with impact drill (the 

specification of drill head should be the same as the plastic 

expansion particle) and then fill the plastic expansion particles 

2. Indoor Unit:

(1) There should be no obstruction near air inlet and air outlet.
(2) Select a location where the condensation water can be 
dispersed easily andwont affect other people.
(3) Select a location which is convenient to connect the 
outdoor unit and near the power socket.
(4) Select a location which is out of reach for children.
(5)  The location should be able to withstand the weight of 
indoor unit and wont increase noise and vibration.
(6) 

The appliance must be installed 2.5m above floor.

(7) Dont install the indoor unit right above the electric 
appliance.

(8) Please try your best to keep way from fluorescent lamp.

3. Outdoor Unit:

(1) Select a location where the noise and outflow air emitted by 

the outdoor unit will not affect neighborhood.
(2) The location should be well ventilated and dry, in which 
the outdoor unit wont be exposed directly to sunlight or strong 
wind.
(3) The location should be able to withstand the weight of 
outdoor unit.
(4) Make sure that the installation follows the requirement of 
installation dimension diagram.
(5) Select a location which is out of reach for children and far 
away from animals or plants.If it is unavoidable, please add 
fence for safety purpose.

Note:

1. Basic Requirement:

Installing the unit in the following places may cause 
malfunction. If it is unavoidable, please consult the local dealer:

(1) The place with strong heat sources, vapors, flammable or 

explosive gas, or volatile objects spread in the air.
(2) The place with high-frequency devices (such as welding 
machine, medical equipment).
(3) The place near coast area.
(4) The place with oil or fumes in the air. 
(5) The place with sulfureted gas.
(6) Other places with special circumstances.
(7) The appliance shall not be installed in the laundry.
(8) It’s not allowed to be installed on the unstable or motive 
base structure (such as truck) or in the corrosive
environment (such as chemical factory).

Summary of Contents for OTEC ICHQ Series

Page 1: ...IEWQ ICHQ Series High Wall Inverter Installation Manual ...

Page 2: ... Maintenance 2 3 Installation 5 3 1 Installation Dimension Diagram 5 3 2 Installation Parts checking 7 3 3 Selection of Installation Location 7 3 4 Requirement For Electric Connection 7 3 5 Installation of Indoor Unit 7 3 6 Installation of Outdoor Unit 10 3 7 Vacuum Pumping and Leak Detection 11 3 8 Check after Installation and Test Operation 11 ...

Page 3: ...1 Technical Information 1 Summary Part Ⅰ Technical Information Indoor Unit Outdoor Unit IEWQ036J3A RWI100 ICHQ036J3A RLH100 Remote Controller ...

Page 4: ...ithout plug an air switch must be installed in the circuit The air switch should be all pole parting and the contact parting distance should be more than 3mm 12 Make sure all wires and pipes are connected properly and the valves are opened before energizing 13 Check if there is electric leakage on the unit body If yes please eliminate the electric leakage 14 Replace the fuse with a new one of the ...

Page 5: ...ed 4 If there is refrigerant leakage please take sufficient measure to minimize the density of refrigerant 5 Never touch the refrigerant piping or compressor without wearing glove to avoid scald or frostbite Refrigerant Safety Precautions Improper installation may lead to fire hazard explosion electric shock or injury Installation Safety Precautions connection pipe is not yet connected air will be...

Page 6: ... 4 Electroprobe 7 Electronic leakage detector 10 Pipe pliers pipe cutter 2 Screw driver 5 Universal meter 8 Vacuum pump 11 Pipe expander pipe bender 3 Impact drill drill head electric drill 6 Torque wrench open end wrench inner hexagon spanner 9 Pressure meter 12 Soldering appliance refrigerant container ...

Page 7: ...cm At least 15cm At least 250cm Space to the wall S p a c e t o t h e o b s t r u c t i o n r o o l f e h t o t e c a p S Space to the obstruction Drainage pipe Space to the wall Space to the obstruction Space to the obstructio Space to the obstruction A t l e a s t 3 0 0 c m At least 50cm At least 200cm At least 30cm At least 30cm At least 50cm ...

Page 8: ...t Make the bound pipes pass through the wall hole and then connect outdoor unit Neaten the pipes Vacuum pumping and leakage detection Check after installation and test operation Finish installation Note this flow is only for reference please find the more detailed installation steps in this section Select outdoor unit installation location Install the support of outdoor unit select it according to...

Page 9: ...ble Air switch should be included magnet buckle and heating buckle function it can protect the circuit short and overload Caution please do not use the fuse only for protect the circuit 1 Choosing Installation Iocation Recommend the installation location to the client and then confirm it with the client 2 Install Wall mounting Frame 1 Hang the wall mounting frame on the wall adjust it in horizonta...

Page 10: ...eter of Φ70mm on the selected outlet pipe position In order to drain smoothly slant the piping hole on the wall slightly downward to the outdoor side with the gradient of 5 10 As show in Fig 2 Note Insulating pipe Torque wrench Open end wrench Indoor pipe Pipe Union nut Union nut Pipe joint Pipe Hex nut diameter mm Tightening torque N m Φ6 15 20 Φ9 52 30 40 Φ12 45 55 Φ16 60 65 Φ19 70 75 Refer to t...

Page 11: ...llation when binding them When binding to a certain degree separate the indoor power and then separate the drain hose As show in Fig 15 3 Bind them evenly 4 The liquid pipe and gas pipe should be bound separately at the end 2 Make the power connection wire go through the cable cross hole at the back of indoor unit and then pull it out from the front side As show in Fig 12 3 Remove the wire clip co...

Page 12: ...show in Fig 20 4 Connect Indoor and Outdoor Pipes 1 Remove the screw on the handle and valve cover of outdoor unit and then remove the handle and valve cover As show in Fig 21 2 Remove the screw cap of valve and aim the pipe joint at the bellmouth of pipe As show in Fig 22 3 Pretightening the union nut with hand 4 Tighten the union nut with torque wrench Fig 18 Fig 19 Fig 20 Fig 21 Fig 22 1 After ...

Page 13: ...uldnt be higher than the outlet pipe hole of indoor unit As show in Fig 25 2 Slant the drain hose slightly downwards The drain hose Can t be curved raised and fluctuant etc As show in Fig 26 Note The drain hos can t raise upwards Fig 24 Fig 25 2 Test Operation 1 Preparation of test operation The client approves the air conditioner installation Specify the important notes for air conditioner to the...

Page 14: ...OMEGA IEWQ HQ High Wall Inverter Installation Manual IEWQ CHQ I3A IM1R0622 info otecomega com www otecomega com info otecomega com www otecomega com ...

Reviews: