Installation and Maintenance

Electrical Safety Precautions:

2

. Notes for Installation and Maintenance

Safety Precautions: 

Important!

Please read the safety precautions carefully before 

installation and maintenance.

The following contents are very important for installation 

and maintenance.

Please follow the instructions below.

●The installation or maintenance must accord with the

instructions.

●Comply with all national electrical codes and local

electrical codes.

●Pay attention to the warnings and cautions in this

manual.

●All installation and maintenance shall be performed by

distributor or qualified person.

●All electric work must be performed by a licensed

technician according to local regulations and the 

instructions given in this manual.

●Be caution during installation and maintenance. Prohibit

incorrect operation to prevent electric shock, casualty and 

other accidents.

1. Cut off the power supply of air conditioner before

checking and maintenance.

2. The air condition must apply specialized circuit and

prohibit share the same circuit with other appliances.

3. The air conditioner should be installed in suitable

location and ensure the power plug is touchable.

4. Make sure each wiring terminal is connected firmly

during installation and maintenance.

5. Have the unit adequately grounded. The grounding

wire Can't be used for other purposes.

6. Must apply protective accessories such as protective

boards, cable-cross loop and wire clip.

7. The live wire, neutral wire and grounding wire of

power supply must be corresponding to the live wire, 

neutral wire and grounding wire of the air conditioner.  

8. The power cord and power connection wires Can't be

pressed by hard objects.

9. If power cord or connection wire is broken, it must be

replaced by a qualified person.

Warnings

Part 

: Installation and Maintenance 

10. If the power cord or connection wire is not long enough,

please get the specialized power cord or connection wire 

from the manufacture or distributor. Prohibit prolong the wire 

by yourself.

11. For the air conditioner without plug, an air switch must

be installed in the circuit. The air switch should be all-pole 

parting and the contact parting distance should be more than 

3mm.

12. Make sure all wires and pipes are connected properly and

the valves are opened before energizing.

13. Check if there is electric leakage on the unit body. If yes,

please eliminate the electric leakage.

14. Replace the fuse with a new one of the same specification

if it is burnt down; dont replace it with a cooper wire or 

conducting wire.

15. If the unit is to be installed in a humid place, the circuit

breaker must be installed.

To ensure safety, please be mindful of the following precautions.

●When installing or relocating the unit, be sure to keep the

refrigerant circuit free from air or substances other than the 

specified refrigerant.

Any presence of air or other foreign substance in the 

refrigerant circuit will cause system pressure rise or 

compressor rupture, resulting in injury.

●When installing or moving this unit, do not charge the

refrigerant which is not comply with that on the nameplate or 

unqualified refrigerant.

Otherwise, it may cause abnormal operation, wrong action, 

mechanical malfunction or even series safety accident.

●When refrigerant needs to be recovered during relocating or

repairing the unit, be sure that the unit is running in cooling 

mode.Then, fully close the valve at high pressure side (liquid 

valve).About 30-40 seconds later, fully close the valve at 

low pressure side (gas valve), immediately stop the unit and 

disconnect power. Please note that the time for refrigerant 

recovery should not exceed 1 minute.

If refrigerant recovery takes too much time, air may be 

sucked in and cause pressure rise or compressor rupture, 

resulting in injury.

●During refrigerant recovery, make sure that liquid valve and

gas valve are fully closed and power is disconnected before 

detaching the connection pipe.

If compressor starts running when stop valve is open and 

connection pipe is not yet connected, air will be sucked in 

and cause pressure rise or compressor rupture, resulting in 

injury.

●When installing the unit, make sure that connection pipe is

securely connected before the compressor starts running.

If compressor starts running when stop valve is open and 

Summary of Contents for OTEC ICHQ Series

Page 1: ...IEWQ ICHQ Series High Wall Inverter Installation Manual ...

Page 2: ... Maintenance 2 3 Installation 5 3 1 Installation Dimension Diagram 5 3 2 Installation Parts checking 7 3 3 Selection of Installation Location 7 3 4 Requirement For Electric Connection 7 3 5 Installation of Indoor Unit 7 3 6 Installation of Outdoor Unit 10 3 7 Vacuum Pumping and Leak Detection 11 3 8 Check after Installation and Test Operation 11 ...

Page 3: ...1 Technical Information 1 Summary Part Ⅰ Technical Information Indoor Unit Outdoor Unit IEWQ036J3A RWI100 ICHQ036J3A RLH100 Remote Controller ...

Page 4: ...ithout plug an air switch must be installed in the circuit The air switch should be all pole parting and the contact parting distance should be more than 3mm 12 Make sure all wires and pipes are connected properly and the valves are opened before energizing 13 Check if there is electric leakage on the unit body If yes please eliminate the electric leakage 14 Replace the fuse with a new one of the ...

Page 5: ...ed 4 If there is refrigerant leakage please take sufficient measure to minimize the density of refrigerant 5 Never touch the refrigerant piping or compressor without wearing glove to avoid scald or frostbite Refrigerant Safety Precautions Improper installation may lead to fire hazard explosion electric shock or injury Installation Safety Precautions connection pipe is not yet connected air will be...

Page 6: ... 4 Electroprobe 7 Electronic leakage detector 10 Pipe pliers pipe cutter 2 Screw driver 5 Universal meter 8 Vacuum pump 11 Pipe expander pipe bender 3 Impact drill drill head electric drill 6 Torque wrench open end wrench inner hexagon spanner 9 Pressure meter 12 Soldering appliance refrigerant container ...

Page 7: ...cm At least 15cm At least 250cm Space to the wall S p a c e t o t h e o b s t r u c t i o n r o o l f e h t o t e c a p S Space to the obstruction Drainage pipe Space to the wall Space to the obstruction Space to the obstructio Space to the obstruction A t l e a s t 3 0 0 c m At least 50cm At least 200cm At least 30cm At least 30cm At least 50cm ...

Page 8: ...t Make the bound pipes pass through the wall hole and then connect outdoor unit Neaten the pipes Vacuum pumping and leakage detection Check after installation and test operation Finish installation Note this flow is only for reference please find the more detailed installation steps in this section Select outdoor unit installation location Install the support of outdoor unit select it according to...

Page 9: ...ble Air switch should be included magnet buckle and heating buckle function it can protect the circuit short and overload Caution please do not use the fuse only for protect the circuit 1 Choosing Installation Iocation Recommend the installation location to the client and then confirm it with the client 2 Install Wall mounting Frame 1 Hang the wall mounting frame on the wall adjust it in horizonta...

Page 10: ...eter of Φ70mm on the selected outlet pipe position In order to drain smoothly slant the piping hole on the wall slightly downward to the outdoor side with the gradient of 5 10 As show in Fig 2 Note Insulating pipe Torque wrench Open end wrench Indoor pipe Pipe Union nut Union nut Pipe joint Pipe Hex nut diameter mm Tightening torque N m Φ6 15 20 Φ9 52 30 40 Φ12 45 55 Φ16 60 65 Φ19 70 75 Refer to t...

Page 11: ...llation when binding them When binding to a certain degree separate the indoor power and then separate the drain hose As show in Fig 15 3 Bind them evenly 4 The liquid pipe and gas pipe should be bound separately at the end 2 Make the power connection wire go through the cable cross hole at the back of indoor unit and then pull it out from the front side As show in Fig 12 3 Remove the wire clip co...

Page 12: ...show in Fig 20 4 Connect Indoor and Outdoor Pipes 1 Remove the screw on the handle and valve cover of outdoor unit and then remove the handle and valve cover As show in Fig 21 2 Remove the screw cap of valve and aim the pipe joint at the bellmouth of pipe As show in Fig 22 3 Pretightening the union nut with hand 4 Tighten the union nut with torque wrench Fig 18 Fig 19 Fig 20 Fig 21 Fig 22 1 After ...

Page 13: ...uldnt be higher than the outlet pipe hole of indoor unit As show in Fig 25 2 Slant the drain hose slightly downwards The drain hose Can t be curved raised and fluctuant etc As show in Fig 26 Note The drain hos can t raise upwards Fig 24 Fig 25 2 Test Operation 1 Preparation of test operation The client approves the air conditioner installation Specify the important notes for air conditioner to the...

Page 14: ...OMEGA IEWQ HQ High Wall Inverter Installation Manual IEWQ CHQ I3A IM1R0622 info otecomega com www otecomega com info otecomega com www otecomega com ...

Reviews: